Fluke Fluke 312 Digital Clamp Meter
The Fluke 312 Digital Clamp Meter is a high quality, economical product with an AC range of 1000A and a resolution of up to 0.01A. It can meet the testing needs of most industrial applications and meet the needs of maintenance and maintenance. Meets three types of 600 volts and two types of 1000 volt safety standards, safe and reliable.One year warranty with a carrying case, test leads and instructions. Features - 1000A AC current range
- High resolution of 0.01A
- 750V AC/1000VDC voltage range
- With diode test function
- CAT III 600V, CAT II 1000V safety rating
- Opening size 36mm
- Operating temperature: 0 ° C to 40 ° C
- Working altitude of 2000m
- Battery: 9V
- 1 year warranty
| |
Technical Parameters Technical indicators |
AC current (50-500Hz) | Range | 40.00A | | 400.0A | | 1000A | Resolution | 0.01A | | 0.1A | | 1A | Accuracy | 1.9%±5 words | | 50-60Hz | | 2.5%±5 words | | 60-500Hz | |
AC voltage (50-500Hz) | Range | 400.0V/750V | Resolution | 0.1V/1V | Accuracy | 1.5% ± 5 words | |
DC voltage | Range | 400.0V | | 1000V | Resolution | 0.1V/1V | Accuracy | 1% ± 2 words | |
resistance | Range | 400.0Ω | | 4000Ω | Resolution | 0.1Ω/1Ω | Accuracy | 1% ± 3 words | |
input resistance | |
Maximum and minimum | Maximum and minimum | 500ms | |
On and off | |
Secondary tube test | Secondary tube test | To 2V | |
Peak | |
Automatic shut-down** | Automatic shut-down** | 30 minutes | |
Jaw | |
Fluke 317/319 True RMS AC/DC Digital Clamp Meter / Ammeter
The Fluke 317/319 high-performance multi-function digital clamp-on ammeter is tailored to the needs of electrical engineers for the functional design requirements of clamp meters. Fluke 317/319 digital clamp ammeter provides higher accuracy current measurement, AC increased from 1.9% to 1.5%; DC increased from 2.5% to 1.5%, accurate 40A small range high accuracy current test - 0.01A high resolution Rate, 1.6% high precision measurement. Engineers measure small currents much more often than large currents.Basic overviewThe Fluke 317/319 True RMS AC-DC Digital Clamp Meter has an ergonomic design and its streamlined shape makes it easier to hold in your hand. These slim, rugged digital clamp ammeters are ideal for easy 1000A current measurement (319) and for use in confined spaces. The 317 and 319 have an accurate 40 A small range. In addition to a range of test functions, the FLUKE 319 digital clamp ammeter also features start-up current and frequency for easy measurement of motors and lighting. Features - Unique 40A small range, high accuracy current test - 0.01A high resolution, 1.6% high precision measurement
- The pliers are slim and lightweight, making them more suitable for use in confined spaces.
- Large backlit display for easy reading in dark environments
- Start current function (319) to measure the starting current of devices such as motors and lighting
- Current frequency measurement
- Digital clamp meter accuracy is higher than 0.01A and 0.1V
- 1000A AC/DC Current Measurement (319)
- 600V AC/DC voltage measurement
- 4000Ω resistance measurement
- Digital clamp meter sensitive on-off measurement
- Automatic shutdown function to maximize battery life so that the meter can work when needed
- Display retention function to keep measurement results on the screen
- One year warranty
| |
Technical Parameters Technical specifications |
Digital display frequency | |
Battery low indicator | |
power supply | |
Digital clamp meter jaw opening | |
Clamp opening | |
Digital clamp meter size (length X width X height) | | 6.39 in x 2.29 in x 1.20 in | | (162.4 mm x 58.25 mm x 30.5 mm) | |
Digital clamp meter weight | |
Automatic range | |
Safety | | CE | | EN/IEC 61010-1 and IEC 61010-2-032 | | Installation category III, 600V working environment | |
317 Technical Specifications |
Alternating current | Range | 40.00 A, 600.0 A | Resolution | 0.01 A, 0.1 A | Accuracy | 1.6% ± 6 words (50-60 Hz) {40 A} | | 2.5% ± 8 words (60-500 Hz) {40 A} | | 1.5% ± 5 words (50-60 Hz) {600 A} | | 2.5% ± 5 words (60-500 Hz) {600 A} | Crest Factor add 2% into spec for CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A | Communication response | Valid value | |
DC | Range | 40.00 A, 600.0 A | Resolution | 0.01 A, 0.1 A | Accuracy | 1.6% ± 6 words (40 A) | | 1.5% ± 5 words (600 A) | |
AC voltage | Range | 600.0 V | Resolution | 0.1 V | Accuracy | 1.5% ± 5 words (20-500Hz) | Communication response | Effective straight | |
DC voltage | Range | 600.0 V | Resolution | 0.1 V | Accuracy | 1% ± 4 words | |
Resolution | Range | 400.0 Ω, 4000 Ω | Resolution | 0.1 Ω, 1 Ω | Accuracy | 1% ± 5 words | |
On-off measurement | |
Starting current | Response time | incompatible | |
Frequency measurement | Range | incompatible | Accuracy | incompatible | Trigger level | incompatible | |
319 Technical Specifications |
Alternating current | Range | 40.00 A, 600.0 A, 1000 A | Resolution | 0.01 A, 0.1 A, 1 A | Accuracy | 1.6% ± 6 words (50-60 Hz) {40 A} | | 2.5% ± 8 words (60-500 Hz) {40 A} | | 1.5% ± 5 words (50-60 Hz) {600/1000 A} | | 2.5% ± 5 digit (60-500 Hz) {600/1000 A} | Crest Factor and 2% to size CF > 2 | 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A | Communication response | Valid value | |
DC | Range | 40.00 A, 600.0 A, 1000 A | Resolution | 0.01 A, 0.1 A, 1 A | Accuracy | 1.6% ± 6 words (40 A) | | 1.5% ± 5 words (600/1000 A) | |
AC voltage | Range | 600.0 V | Resolution | 0.1 V | Accuracy | 1.5% ± 5 words (20-500Hz) | Communication response | Effective straight | |
DC voltage | Range | 600.0 V | Resolution | 0.1 V | Accuracy | 1% ± 4 words | |
Resolution | Range | 400.0 Ω | | 4000 Ω | Resolution | 0.1 Ω | | 1 Ω | Accuracy | 1% ± 5 words | |
On-off measurement | |
Starting current | Response time | 100 milliseconds | |
Frequency measurement | Range | 5.0 - 500.0 Hz | Accuracy | 0.5% ± 5 words | Trigger level | 10 - 100 Hz ≥ 5 A, 5 - 10 Hz, 100 - 500 Hz ≥ 10 A | |
Environmental parameters: |
Digital clamp meter operating temperature | | 14°F to 122°F (-10 °C to 50 °C) | |
Storage temperature | | -40 °F to 140 °F (-40 °C to 60 °C) | |
Working humidity | | No fog (< 50 °F) (< 10 °C) | | 90 % RH (50 °F to 86 °F) (10 °C to 30 °C) | | 75 % RH (86 °F to 104 °F) (30 °C to 40 °C) | | 45 % RH (104 °F to 122 °F) (40 °C to 50 °C) | | No fog | |
Working altitude | | 2000 meters above sea level | |
Storage altitude | | 12,000 meters above sea level | |
IP indicator | |
Digital clamp meter vibration requirements | | Random MIL-PRF-28800F Class 2, 5-500 Hz, 30 minutes per axis | |
Drop test requirement | |
EMI, RFI, EMC | | Non-specifically, as for the EMC environment, ≥ 0.1 V/m | |
Temperature Coefficient | | 0.1x (prescribed accuracy) / °C | | (<64 °F or > 82° F) | | (<18 °C or > 28 °C) | |
Fluke 362 Clamp / Fluke 365 True RMS AC/DC Clamp Meter / Ammeter
The Fluke 362 is a small, light and thin pocket-type pliers. The thin and small beak-type clamps make it easier to measure dense cables. It makes the clamp meter easier to use and is durable. Basic maintenance tools that are easy to carry.
Fluke 365 true RMS AC-DC clamp meter with detachable clamp head design, light body, more suitable for measurement in a small space; thin and small bird-nosed clamp head, easier to measure dense cable; built-in Flashlights and backlighting make readings easier. Features - Small, light and thin body
- The small and thin clamp head design makes the measurement of dense cable easy, and the use of the clamp meter is simpler.
- Compact design for one-handed operation
- Large screen 2000 word display
- 200A AC and DC, 600V AC and DC voltage range
- 3000Ω resistance range, continuity test
- Zero function, the display can be cleared for DC measurement
- Reading hold
- Security level: CAT III 600V
| |
Fluke 365 true RMS AC/DC clamp meter/current meter, light body, unique separable clamp head design, 1m extension cord, extension cord can be stowed when not in useØ Triangular small and thin clamp head design makes the measurement of dense cable easy Ø Built-in flashlight, backlight Ø Compact design, one-handed operation Ø large screen 2000 word display Ø 200A AC and DC current, 600V AC and DC voltage range Ø 6000Ω resistance range, continuity test Ø Zero function, the display can be cleared for DC measurement Ø True RMS measurement, can accurately measure nonlinear load circuit Ø readings remain |
Technical parameters (Fluke 362) | Range | Resolution | Accuracy |
Alternating current | 200 | 0.1A | 2 % ± 5 words (45-65Hz) 2.5% ± 5 words (65-400Hz) |
DC | 200 | 0.1A | 2 % ± 5 words |
AC voltage | 600 V | 0.1 V | 1.5 % ± 5 words (45-400Hz) |
DC | 600 V | 0.1 V | 1 % ± 5 words |
resistance | 300/3000Ω | 0.1/1Ω | 1 % ± 5 words |
On-off detection | <=70Ω |
maintain | • |
size | Length, width and height | 205×60×22 |
| Clamp opening | 18mm |
| Weight (g) | 196 |
Security Level | CAT III 600 V |
warranty period | 2 years |
Technical parameters (Fluke 365) Technical Parameters |
Measurable conductor diameter | 0.71" or 18 mm max |
Operating temperature | -14 to 122oF (-10 to 50oC) |
Storage temperature | -40 to 140oF (-40 to 60oC) |
Working humidity | < 90% @ 10 to 30 oC, < 75% @ 30 to 40oC |
Working altitude | 0 to 2000 m |
Clamp ammeter size | 225 x 65 x 46 mm, (8.858 x 2.559 x 1.811 in.) |
Clamp type ammeter weight | 275g, (10 oz.) |
Temperature Coefficient | 0.01% oC (<18oC or > 28oC) |
warranty period | 3 years |
-
-
Thiết bị hiệu chuẩn dòng điện, điện áp FLUKE , Fluke F705/F707/F715/F709/F709H, Calibrator FLUKE715 Voltage Current Calibrator
Liên hệ
-
-
Máy hiệu chuẩn áp suất Fluke, Fluke F717/F718/F719/F719Pro, pressure calibrator FLUKE718/719 pressure calibrator
Liên hệ
-
-
ĐỒNG HỒ ĐO ĐIỆN CHỈ THỊ PHA, Fluke F9040 phase sequence indicator ,F9062 motor phase sequence indicator FLUKE2042 cable tester
Liên hệ
-
-
Súng đo nhiệt độ bằng hồng ngoại ,FLUKE F572/F574, infrared thermometer ,FLUKE574 thermometer -30-900 °C
Liên hệ
-
-
Súng đo nhiệt độ bằng hồng ngoại ,Fluke F59/F59E/MT4MAX/MT4MAX+/F62MAX/F62MAX+/ST20MAX Thermometer Kit
Liên hệ
-
-
Thiết bị đo nhiệt độ tiếp xúc, FLUKE F51-II/F52-II/F53-IIB/F54-IIB, thermometer F52-2/F53-2B/F54-2B
Liên hệ
-
-
Ampe kìm đo dòng nhỏ,Fluke F342/LH41A small current clamp meter FLUKE342 clamp meter F902FC clamp meter F360
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke F353/F355 Clamp Meter FLUKE353/FLUKE355, Clamp Meter High Current 2000A
Liên hệ
-
-
Ampe kìm đo dòng rò, Fluke F368 F368FC F369 F369FC, leakage current clamp table ,FLUKE368FC FLUKE369FC
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke F323/F324/F325 Clamp Meter
Liên hệ
-
-
Thiết bị kiểm tra điện áp, Fluke FLUKE T6-600/T6-1000, non-contact voltage clamp meter, T5-600/T5-1000 voltage clamp
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke FLUKE373/F374FC/F375FC/F376FC, FLUKE381/FLUKE376
Liên hệ