Công ty TNHH công nghệ số Tân Thành

Thiết bị kiểm tra điện áp, Fluke FLUKE T6-600/T6-1000, non-contact voltage clamp meter, T5-600/T5-1000 voltage clamp

  • Đăng ngày 08-11-2018 12:15:25 PM - 592 Lượt xem
  • Mã sản phẩm: T6-600/T6-1000, T5-600/T5-1000

  • Tình trạng sản phẩm:


    T6-600/T6-1000 Non-contact voltage clamp meter

    Voltage measurement... no test leads required
    It is possible to measure up to 600V (T6-600) or 1000 V (T6-1000) through the open cross without testing the lead wire to contact the live voltage.
    Voltage. + No need to open the cover or remove the wiring nut. Suitable for AWG 4/0 (120 mm2) specification grades with load currents up to 200 A. Can be competent for more complex and diverse work. The operation is safer. faster. It's easier to use.


     

    Measurement Specifications (T6-600)
    Features Need to 
    test the wire
    Range Resolution Accuracy [1]
    FieldSense  
    AC voltage true RMS
    no 600 V 1 V ±(3% + 3 counts) 45 Hz - 66 Hz [2][3]
    FieldSense 
    AC current true RMS
    no 200.0 A 0.1 A ±(3% + 3 ) 45 Hz - 66 Hz
    FieldSense 
    frequency (Hz)
    no   1 Hz ±(1% + 2 counts) [3]
    AC voltage true RMS Yes 600 V 1 V ±(1.5% + 2 ) 45 Hz - 66 Hz
    DC voltage Yes 600 V 1 V ±(1% + 2)
    resistance Yes 2000 Ω 1 Ω ±(1% + 2)
    Security Level   600 V CAT III    
    Accuracy  [1] : ± ([% of reading] + [least significant digit]). Accuracy is valid for one year after calibration, operating from 18 °C to 28 °C (64 °F to 82 °F) and relative humidity to 90%. AC measurement: AC coupling, RMS response. 
    Accuracy  [2] : Increase by 3% without external ground connection. External grounding requires the user to wear insulated gloves, stand on an insulated ladder or otherwise insulate the ground. 
    Accuracy  [3] : FieldSense can be specified from 16 V to full scale.
    Measurement Specifications (T5-1000)
    Features Need to test the wire Range Resolution Accuracy [1]
    FieldSense  
    AC voltage true RMS
    no 1000 V 1 V ±(3 % + 3 counts) 45 Hz - 66 Hz[2][3]
    FieldSense 
    AC current true RMS
    no 200.0 A 0.1 A ±(3% + 3 counts) 45 Hz - 66 Hz
    FieldSense 
    frequency (Hz)
    no 45 Hz – 66 Hz 1 Hz ±(1% + 2 counts) [3]
    AC voltage true RMS Yes 1000 V 1 V ±(1.5% + 2 counts) 45 Hz - 66 Hz
    DC voltage Yes 1000 V 1 V ±(1% + 2 counts)
    resistance Yes 2000 Ω 1 Ω ±(1% + 2 counts)
    Yes 20.00 kΩ 0.01 kΩ
    Yes 100.0 kΩ 0.1 kΩ
    Security Level   1000 V CAT III 
    600 V CAT IV
       
    Accuracy  [1] : ± ([% of reading] + [least significant digit]). Accuracy is valid for one year after calibration, operating from 18 °C to 28 °C (64 °F to 82 °F) and relative humidity to 90%. AC measurement: AC coupling, RMS response. 
    Accuracy  [2] : Increase by 3% without external ground connection. External grounding requires the user to wear insulated gloves, stand on an insulated ladder or otherwise insulate the ground. 
    Accuracy  [3] : FieldSense can be specified from 16 V to full scale.
    General technical indicators
    calibration 1 year calibration cycle
    size 61.1 x 259.3 x 43.8 mm
    Jaw opening 17.8 mm
    weight 0.35 kg (0.78 lb)
    Temperature 
    work: 
    storage:
     
    -10 °C to +50 °C (14 °F to 122 °F) 
    -30 °C to +60 °C (-22 °F to +140 °F)
    Humidity 
    work: 
    storage:
     
    2,000 meters (6,562 feet) 
    10,000 meters (32,808 feet)
    Relative humidity 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) 
    0% to 75%, 30 °C to 40 °C (86 °F to 104 °F) 
    0% to 45%, 40 ° C to 50 ° C (104 ° F to 122 ° F)
    Battery model and service life Two AA size alkaline batteries (IEC LR6); 360 hours standard battery life; 200 hours battery life (using FieldSense)
    Temperature Coefficient 0.1 x (specified accuracy) / °C (<18°C or >28 °C) 
    (< 64.4 °F or > 82.4 °F)
    Security Level IEC/EN 61010-1: Pollution Degree 2
    Electromagnetic environment IEC/EN 61326-1: Portable

    Fluke T5-600/T5-1000 Voltage Fluctuation Tester

    Test pen with open clamp (OpenJawTM) current and voltage fluctuation test function 
    With the compact Fluke T5 voltage fluctuation test pen, voltage fluctuations, on-off and current measurements can be done. You only need to select the voltage, ohms or current function, and the rest is done by the test pen. With the OpenJawTM Current-Voltage Fluctuation Test, you can measure currents up to 100A without disconnecting the circuit. The sturdy test leads can be neatly packed into the slot on the back of the test pen, making it easy to put the T5 in your pocket. The detachable SlimReachTM test probe is tailored to the local national power standards. Voltage fluctuation test leads are available for optional accessories such as clips and professional probes. With the optional H5 holster, the user can hold the T5 on the waist. The T5 is available in 600V and 1000V models.
       Features 
    • Automatic AC/DC voltage fluctuation test with accurate digital resolution 
    • Display resistance up to 1000W 
    • Simple and accurate open jaw (OpenJawTM) current and voltage fluctuation test function 
    • On-off buzzer 
    • Compact design, probe collection card slot 
    • Can withstand 10-foot (3m) drops 
    • Detachable SlimReachTM probe probe, tailored to the local power standard 
    • Voltage fluctuation test leads are compatible with Fluke's universal accessories 
    • Available in 600V and 1000V models 
    • Longer connection distance than spiral tube test pen 
    • Auto off mode saves battery power 
    • Optional leather case, you can put the test probe on your waist and clean the test line neatly


    Technical Parameters
    Technical indicators
    On-off buzzer
    Threshold:  <25W open, >400W close
    Voltage indicator LED
    Threshold:  30V ac protection
    Environmental parameters:
    Voltage fluctuation test operating temperature
       -10 °C to 50 °C
    Storage temperature
       -30 °C to 60 °C
    Humidity (no condensation)
       0% to 95% (5 °C to 30 °C)
       0% to 75% (30 °C to 40 °C)
       0% to 45% (40 °C to 50 °C)
    Dustproof / waterproof
       Yes
    Running altitude
       Up to 2000 meters
    Voltage fluctuation test temperature coefficient
       0.1 x (current) / °C (<18 °C or >28 °C)
    Safety technical parameters
    Overvoltage category
    T5-600:  600V ac/dc, CAT III
    T5-1000:  1000V ac/dc, CAT III 
    600V ac/dc, CAT IV
    Agency certification
       UL, CSA and VDE
    Voltage fluctuation test maximum voltage
       Between any terminal and ground
    Mechanical and general parameters
    size
       30.5 x 51 x 203 mm
    weight
       300g
    warranty period
       2 years
    Battery Life
       200 hours for zinc chloride batteries and 400 hours for alkaline batteries
    type of battery
       Two AA model zinc chloride batteries
    Low voltage indicator
       Yes
    Current sensor opening
       12.9 mm
    Calibration cycle
       1 year
    Voltage fluctuation test line
    Types of:  Heavy load, nominally 1000 V flexible test line
       Field replaceable test line terminal for male concealed banana plug 
    Probe:  One red, one black two probes
       One separate Slim-ReachT probe probe in each pair of probes 
    specification:  TP4 4 mm round head


     
         

     



    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ:
    -------------------------------
    CÔNG TY TNHH THIẾT BỊ CÔNG NGHIỆP TTH
    Trụ sở: số 124 ngõ 79 Yên Hoà-Cầu giấy-HN
    Kinh doanh 1 : 0816.861.515
    Kinh doanh 2 : 0836.861.515
    Kinh doanh 3 : 0926.511.515
    Kinh doanh 4 : 0916.861.515
    Kinh doanh 5 : 0888.868.515
    Kinh doanh 6 : 0917.971.515
    Website: http://tanthanh-automation.com
    Website: http://thietbitudongtanthanh.com
    Website: http://diencongnghieptanthanh.com
    Email: tthkinhdoanh@gmail.com
    Email: tthkinhdoanh01@gmail.com

  • Kết nối với chúng tôi