Trang nhất
Dụng cụ cầm tay, dụng cụ toolFluke
Thiết bị kiểm tra điện áp, Fluke FLUKE T6-600/T6-1000, non-contact voltage clamp meter, T5-600/T5-1000 voltage clamp
Đăng ngày 08-11-2018 12:15:25 PM - 731 Lượt xem
Mã sản phẩm: T6-600/T6-1000, T5-600/T5-1000
T6-600/T6-1000 Non-contact voltage clamp meter
Voltage measurement... no test leads required
It is possible to measure up to 600V (T6-600) or 1000 V (T6-1000) through the open cross without testing the lead wire to contact the live voltage.
Voltage. + No need to open the cover or remove the wiring nut. Suitable for AWG 4/0 (120 mm2) specification grades with load currents up to 200 A. Can be competent for more complex and diverse work. The operation is safer. faster. It's easier to use.
Measurement Specifications (T6-600) |
Features | Need to test the wire | Range | Resolution | Accuracy [1] |
FieldSense AC voltage true RMS | no | 600 V | 1 V | ±(3% + 3 counts) 45 Hz - 66 Hz [2][3] |
FieldSense AC current true RMS | no | 200.0 A | 0.1 A | ±(3% + 3 ) 45 Hz - 66 Hz |
FieldSense frequency (Hz) | no | | 1 Hz | ±(1% + 2 counts) [3] |
AC voltage true RMS | Yes | 600 V | 1 V | ±(1.5% + 2 ) 45 Hz - 66 Hz |
DC voltage | Yes | 600 V | 1 V | ±(1% + 2) |
resistance | Yes | 2000 Ω | 1 Ω | ±(1% + 2) |
Security Level | | 600 V CAT III | | |
Accuracy [1] : ± ([% of reading] + [least significant digit]). Accuracy is valid for one year after calibration, operating from 18 °C to 28 °C (64 °F to 82 °F) and relative humidity to 90%. AC measurement: AC coupling, RMS response. Accuracy [2] : Increase by 3% without external ground connection. External grounding requires the user to wear insulated gloves, stand on an insulated ladder or otherwise insulate the ground. Accuracy [3] : FieldSense can be specified from 16 V to full scale. |
Measurement Specifications (T5-1000) |
Features | Need to test the wire | Range | Resolution | Accuracy [1] |
FieldSense AC voltage true RMS | no | 1000 V | 1 V | ±(3 % + 3 counts) 45 Hz - 66 Hz[2][3] |
FieldSense AC current true RMS | no | 200.0 A | 0.1 A | ±(3% + 3 counts) 45 Hz - 66 Hz |
FieldSense frequency (Hz) | no | 45 Hz – 66 Hz | 1 Hz | ±(1% + 2 counts) [3] |
AC voltage true RMS | Yes | 1000 V | 1 V | ±(1.5% + 2 counts) 45 Hz - 66 Hz |
DC voltage | Yes | 1000 V | 1 V | ±(1% + 2 counts) |
resistance | Yes | 2000 Ω | 1 Ω | ±(1% + 2 counts) |
Yes | 20.00 kΩ | 0.01 kΩ |
Yes | 100.0 kΩ | 0.1 kΩ |
Security Level | | 1000 V CAT III 600 V CAT IV | | |
Accuracy [1] : ± ([% of reading] + [least significant digit]). Accuracy is valid for one year after calibration, operating from 18 °C to 28 °C (64 °F to 82 °F) and relative humidity to 90%. AC measurement: AC coupling, RMS response. Accuracy [2] : Increase by 3% without external ground connection. External grounding requires the user to wear insulated gloves, stand on an insulated ladder or otherwise insulate the ground. Accuracy [3] : FieldSense can be specified from 16 V to full scale. |
General technical indicators |
calibration | 1 year calibration cycle |
size | 61.1 x 259.3 x 43.8 mm |
Jaw opening | 17.8 mm |
weight | 0.35 kg (0.78 lb) |
Temperature work: storage: | -10 °C to +50 °C (14 °F to 122 °F) -30 °C to +60 °C (-22 °F to +140 °F) |
Humidity work: storage: | 2,000 meters (6,562 feet) 10,000 meters (32,808 feet) |
Relative humidity | 0% to 90%, 5 °C to 30 °C (41 °F to 86 °F) 0% to 75%, 30 °C to 40 °C (86 °F to 104 °F) 0% to 45%, 40 ° C to 50 ° C (104 ° F to 122 ° F) |
Battery model and service life | Two AA size alkaline batteries (IEC LR6); 360 hours standard battery life; 200 hours battery life (using FieldSense) |
Temperature Coefficient | 0.1 x (specified accuracy) / °C (<18°C or >28 °C) (< 64.4 °F or > 82.4 °F) |
Security Level | IEC/EN 61010-1: Pollution Degree 2 |
Electromagnetic environment | IEC/EN 61326-1: Portable |
Fluke T5-600/T5-1000 Voltage Fluctuation Tester
Test pen with open clamp (OpenJawTM) current and voltage fluctuation test function
With the compact Fluke T5 voltage fluctuation test pen, voltage fluctuations, on-off and current measurements can be done. You only need to select the voltage, ohms or current function, and the rest is done by the test pen. With the OpenJawTM Current-Voltage Fluctuation Test, you can measure currents up to 100A without disconnecting the circuit. The sturdy test leads can be neatly packed into the slot on the back of the test pen, making it easy to put the T5 in your pocket. The detachable SlimReachTM test probe is tailored to the local national power standards. Voltage fluctuation test leads are available for optional accessories such as clips and professional probes. With the optional H5 holster, the user can hold the T5 on the waist. The T5 is available in 600V and 1000V models. | Features - Automatic AC/DC voltage fluctuation test with accurate digital resolution
- Display resistance up to 1000W
- Simple and accurate open jaw (OpenJawTM) current and voltage fluctuation test function
- On-off buzzer
- Compact design, probe collection card slot
- Can withstand 10-foot (3m) drops
- Detachable SlimReachTM probe probe, tailored to the local power standard
- Voltage fluctuation test leads are compatible with Fluke's universal accessories
- Available in 600V and 1000V models
- Longer connection distance than spiral tube test pen
- Auto off mode saves battery power
- Optional leather case, you can put the test probe on your waist and clean the test line neatly
|
Technical Parameters Technical indicators |
On-off buzzer | Threshold: | <25W open, >400W close | |
Voltage indicator LED | Threshold: | 30V ac protection | |
Environmental parameters: |
Voltage fluctuation test operating temperature | |
Storage temperature | |
Humidity (no condensation) | | 0% to 95% (5 °C to 30 °C) | | 0% to 75% (30 °C to 40 °C) | | 0% to 45% (40 °C to 50 °C) | |
Dustproof / waterproof | |
Running altitude | |
Voltage fluctuation test temperature coefficient | | 0.1 x (current) / °C (<18 °C or >28 °C) | |
Safety technical parameters |
Overvoltage category | T5-600: | 600V ac/dc, CAT III | T5-1000: | 1000V ac/dc, CAT III 600V ac/dc, CAT IV | |
Agency certification | |
Voltage fluctuation test maximum voltage | | Between any terminal and ground | |
Mechanical and general parameters |
size | |
weight | |
warranty period | |
Battery Life | | 200 hours for zinc chloride batteries and 400 hours for alkaline batteries | |
type of battery | | Two AA model zinc chloride batteries | |
Low voltage indicator | |
Current sensor opening | |
Calibration cycle | |
Voltage fluctuation test line | Types of: | Heavy load, nominally 1000 V flexible test line | | Field replaceable test line terminal for male concealed banana plug | Probe: | One red, one black two probes | | One separate Slim-ReachT probe probe in each pair of probes | specification: | TP4 4 mm round head | |
-
-
Thiết bị hiệu chuẩn dòng điện, điện áp FLUKE , Fluke F705/F707/F715/F709/F709H, Calibrator FLUKE715 Voltage Current Calibrator
Liên hệ
-
-
Máy hiệu chuẩn áp suất Fluke, Fluke F717/F718/F719/F719Pro, pressure calibrator FLUKE718/719 pressure calibrator
Liên hệ
-
-
ĐỒNG HỒ ĐO ĐIỆN CHỈ THỊ PHA, Fluke F9040 phase sequence indicator ,F9062 motor phase sequence indicator FLUKE2042 cable tester
Liên hệ
-
-
Súng đo nhiệt độ bằng hồng ngoại ,FLUKE F572/F574, infrared thermometer ,FLUKE574 thermometer -30-900 °C
Liên hệ
-
-
Súng đo nhiệt độ bằng hồng ngoại ,Fluke F59/F59E/MT4MAX/MT4MAX+/F62MAX/F62MAX+/ST20MAX Thermometer Kit
Liên hệ
-
-
Thiết bị đo nhiệt độ tiếp xúc, FLUKE F51-II/F52-II/F53-IIB/F54-IIB, thermometer F52-2/F53-2B/F54-2B
Liên hệ
-
-
Ampe kìm đo dòng nhỏ,Fluke F342/LH41A small current clamp meter FLUKE342 clamp meter F902FC clamp meter F360
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke F353/F355 Clamp Meter FLUKE353/FLUKE355, Clamp Meter High Current 2000A
Liên hệ
-
-
Ampe kìm đo dòng rò, Fluke F368 F368FC F369 F369FC, leakage current clamp table ,FLUKE368FC FLUKE369FC
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke F323/F324/F325 Clamp Meter
Liên hệ
-
-
AMPE KÌM ĐO ĐIỆN, Fluke FLUKE373/F374FC/F375FC/F376FC, FLUKE381/FLUKE376
Liên hệ
-
-
Ampe kìm phân tích công suất, Fluke FLUKE345 power quality analyzer F345 tester FLUKE353/F355 clamp meter
Liên hệ