System performance indicator
Power supply: 220VAC and 24VD
Medium pressure: vacuum ~ 32MPa
Output: DPDT relay (double pole double throw)
Output capacity: 220VAC /5A
Medium temperature: -100 ° C ~ 230 ° C
Resolution: < 0.5PF
Response time: < 0.5s
Delay: 1 to 50s (optional )
High and low alarm: The field can be set to HLFS (high alarm mode) or LLFS (low alarm mode)
Electrical interface: 3/4′′ NPT
Cable: A dedicated connection cable between the split electronic unit and the sensor, with a standard length of 5 meters and a maximum length of 50 meters.
Process connection: NPT threaded mounting (standard), flange mounting (optional)
Shell protection: IP66
Anti-explosion: Exd[ia]iaIICT4
Overview
● When the tilting switch of the vertical suspension is subjected to an external force and the deviation from the vertical position is more than 15 degrees, the mercury contact inside the switch acts and the normally closed contact opens. When the external force is removed, the tilt switch returns to the vertical state, and the mercury contact is closed again. The change of the contact opening and closing of the tilt switch is used to judge the working condition of the protection device, and measures are taken in time to achieve the purpose of safety protection.
● Pay attention to the use of wire rope or chain suspension products during installation. The cable must be kept loose, otherwise it will affect the product movement.
Application range
● Detection of chute or transfer blockage
● Conveyor belt deviation detection
● Dumper unloading detection
● For belt or vibrating feeders with or without material detection
Features
Rugged, corrosion resistant, easy to install, and the control unit is a printed circuit board structure. Adjustable delay to prevent malfunction. Standard Housing Type 20-43-\ExtAlx Type 20-38-Class II All mounting probes are equipped with mounting accessories. Its performance has been proven by thousands of application examples around the world.
Technical specifications
● Rated voltage: AC220V
● Rated current:. 2A
● Rated Temperature: -40 [deg.] - 70 [deg.]
● shell level of protection: NEMA4X.
● Dimensions: W is × H × housing L (mm) 198 × 32 × 210
● Weight: 1.6 Kg
● inclination angle: 15 ° or more
Cảm biến mức, Germany VEGA instrument radar level gauge VEGAPULS 64
Cảm biến mức, Germany VEGA instrument radar level gauge VEGAPULS 69
Cảm biến mức, Germany VEGA instrument radar level gauge VEGAPULS SR68
■ Advantages
- Guided debugging ensures easy setup and time saving.
- Hygienic design without gaps is simple and reliable.
- Easy to install and maintain.
■ Application
VEGAFLEX 83 is suitable for corrosive liquids and hygienic requirements for liquid level measurement. Even in an environment where foam, accumulation, and steam are strong, measurement accuracy is not affected. VEGAFLEX83 is an economical solution for liquid level measurement.
■ Main performance parameters
Scope of application | liquid |
Measuring distance | Cable type (Ф4mm) range 32 meters Bar (Ф8 mm) the amount of process 4 m |
measurement accuracy | ±2 mm |
Working temperature | -40~150°C |
Working environment pressure | -1 to 16 bar (-100 to 1600 KPa) |
■ Measurement principle:
Capacitance measurement is a widely used method for level measurement. The sensor and the container form the two electrodes of a capacitor. The capacitance value changes with the level of the material in the container and is converted into the corresponding level output signal. Cables and rods are available in different versions and have partially insulated cables and rods.
■ Advantages:
- Simple maintenance and long service life.
- Measurement is accurate and reliable.
- Easy installation and setup, cable length is flexible.
■ Application:
VEGACAL66 is used to measure the continuous level of liquid and solid bulk material. The fully insulated cable probe design can be used for both solid level measurement of solid bulk materials and for the measurement of conductive liquid levels. VEGACAL66 is simple and flexible to install, stable in function and safe.
■ Main features:
Scope of application | Conductive liquid, solid bulk material |
Measuring distance | 32 meters |
Working temperature | -50~+150°C |
Working environment pressure | -1 to +40 bar (-100 to +4000 kPa) |
■ Measurement principle:
Used to measure solid and non-conductive liquid media. The probe and the container form the two poles of a capacitor. When the level of the medium changes, the overall capacitance is affected. The change in capacitance is detected by the electronic component and converted into a switching command. The installation location can be determined based on actual conditions.
■ Advantages:
- The measuring range of the probe is up to 6m.
- The installation location can be flexibly changed according to the actual situation.
- Easy to install and maintain.
■ Application:
- Limit detection of solid and non-conductive liquid media, often used in spill or idling protection systems. Suitable for all kinds of working conditions.
■ Main performance parameters:
■ Measurement principle: Capacitance measurement is a widely used method for level measurement. The sensor and the container form the two electrodes of a capacitor. The capacitance value changes with the level of the material in the container and is converted into the corresponding level output signal. Cables and rods are available in different versions and have partially insulated cables and rods. ■ Advantages: - Simple maintenance and wide application. - Measurement is accurate and reliable. - Easy to use and economical. ■ Application: VEGACAL62 is used to measure the continuous level of liquid and solid bulk material. The partially insulated probe design can be used for both solid level measurement and non-conductive liquid level measurement. VEGACAL62 is simple and flexible to install, stable in function and safe. ■ Main features:
| |||||||||
■ Measurement principle:
Used to measure solid and non-conductive liquid media. The probe and the container form the two poles of a capacitor. When the level of the medium changes, the overall capacitance is affected. The change in capacitance is detected by the electronic component and converted into a switching command. The installation location can be determined based on actual conditions.
■ Advantages:
- The measuring range of the probe is up to 6m.
- The installation location can be flexibly changed according to the actual situation.
- Easy to install and maintain.
■ Application:
- Limit detection of solid and non-conductive liquid media, often used in spill or idling protection systems. Suitable for all kinds of working conditions.
■ Main performance parameters:
Scope of application | Solid medium and non-conductive liquid medium |
Measuring distance | 6 meters |
Version material | Part of the insulation rod (insulation material is Teflon) |
Working temperature | -50~200°C |
Working environment pressure | -1 to 64 bar (-100 to 6400 kPa) |
■ Advantages:
- Almost unaffected by the characteristics of the media.
- The medium temperature is from -40 ° C to 150 ° C.
- Working environment pressure from -100kPa to 6400kPa.
- Easy to install and maintain.
■ Application:
Limit detection of liquid media, often used in spill or idling protection systems.
■ Main performance parameters:
- Easy installation and start-up without special commissioning;
- Threaded fixed piezoelectric drive ceramics;
- High reliability;
- the switching point is not affected by the medium;
- Wear-resistant, maintenance-free;
- Belongs to the plics® product range.
Common models:
SG51.XXSGBCPM
■ Advantages:
- Almost unaffected by the characteristics of the media.
- The medium temperature is from -50 ° C to 250 ° C.
- Working environment pressure from -100kPa to 6400kPa.
- Easy to install and maintain.
■ Application:
Limit detection of liquid media, often used in spill or idling protection systems.
■ Main performance parameters:
- SIL2 certification;
- Easy installation and start-up without special commissioning;
- Threaded fixed piezoelectric drive ceramics;
- High reliability;
- the switching point is not affected by the medium;
- Wear-resistant, maintenance-free;
- Belongs to the plics® product range.
Common models:
VB61.XXGBVXPRX
■ Advantages:
- Almost unaffected by the characteristics of the media.
- The medium temperature is from -50 ° C to 250 ° C.
- Working environment pressure from -100kPa to 6400kPa.
- Easy to install and maintain.
■ Application:
Limit detection of liquid media, often used in spill or idling protection systems.
■ Main performance parameters:
- SIL2 certification;
- Easy installation and start-up without special commissioning;
- Threaded fixed piezoelectric drive ceramics;
- High reliability;
- the switching point is not affected by the medium;
- Wear-resistant, maintenance-free;
- Belongs to the plics® product range.
Common models:
SG61.XXGBVTMRX
■ Measuring principle
Ultrasonic waves from 35 kHz to 70 kHz are emitted through the probe, and the ultrasonic waves are reflected by the measured medium and then re-received by the probe. Ultrasonic waves propagate at the speed of sound waves, and the time from sound wave emission to reflection reception is proportional to the distance from the probe to the surface of the measured medium. The VEGASON series of sensors imported from Germany use the latest micro-processing technology and the unique ECHOFOX software to accurately analyze the level echo, eliminate false reflections and accurately calculate the distance from the probe to the surface of the measured medium. By setting the height dimension of the input container, the distance value in the upper space can be converted into a signal proportional to the level.
■ Advantages
- Maintenance free and widely available.
- Measurement is accurate and reliable.
- Easy to use and economical.
■ Application
VEGASON62 is used to measure the continuous level of liquid and solid bulk material. It is suitable for liquid storage tanks and open storage tanks, as well as small storage tanks and open containers for solid bulk materials. VEGASON62 is economical and practical, simple and flexible to install, and can be set without media.
■ Main performance parameters
Scope of application | Liquid, solid bulk material |
Measuring distance | Liquid: 0.4 to 8 meters, solid: 0.4 to 3.5 meters |
measurement accuracy | ±10 mm |
Working temperature | -40~+80°C |
Working environment pressure | -0.2 to +2 bar (-20 to +200 kPa) |
VEGAPULS 66 is used for continuous measurement of liquid levels under harsh process conditions. It is particularly suitable for continuous measurement of liquid levels in storage vessels, risers and process vessels. Since the antennas are available in different versions, they have a wide range of applications.
■ Main performance parameters
Scope of application | Level measurement in storage tanks or working containers in harsh environments |
Measuring distance | 35 meters |
measurement accuracy | ±8 mm |
Working temperature | -60~+400°C |
Working environment pressure | -1 to +160bar (-100 to +16000 kPa) |
VEGA level measuring instrument
VEGA ultrasonic level measuring instrument SON61/62/63 series
VEGA radar level measuring instrument VEGAPULS61/62/63/65/66/68 series
for measuring liquid and solid medium with different density and surface characteristics, measuring The flow and distance of the open channel.
If you are interested in our products, please write to: ukong@u-kong.com Business Line: 180-7313-9090 Fax: 0731-89822820 Q:26256 34299, from the selection of your working conditions to one-stop Solution, we will give you a satisfactory reply as soon as possible!
VEGASON 61 VEGASON61 SN61CXAGHKCXX 4-20mA HART 0-5m
VEGAPULS 68 PS68.XXEGD5HAMXK
An integrated ultrasonic sensor for continuous level measurement is
suitable for measuring liquid or solid media, especially for measuring water or wastewater.
Advantages
- PVDF probe with EPDM seal and integrated temperature sensing for calibrating sonic run time
- Accuracy ±10 mm
- ECHOFOX - Signal analysis processing with advanced fuzzy logic
- via PLICSCOM, HART-programmer or computer Commissioning
- belongs to the plics product range
Measuring range Liquid: 0.25 ... 5 m
solid: 0.25 ... 2 m
process connection thread G1 1/2A, material: PVDF
process temperature -40 ... +80 °C
process pressure -0,2 ... +2 bar
(-20 ... +200 kPa)
The VEGASON 62
integrated ultrasonic sensor for continuous level measurement is
suitable for measuring liquid or solid media, in particular for measuring water or wastewater.
Advantages
- PVDF probe with EPDM seal and integrated temperature sensing for calibrating sonic run time
- Accuracy ±10 mm
- ECHOFOX - Signal analysis processing with advanced fuzzy logic
- via PLICSCOM, HART-programmer or computer Commissioning
- belongs to the plics product range
Measuring range Liquid: 0.4 ... 8 m
solid: 0.4 ... 3.5 m
process connection thread G2A, material: PVDF
process temperature -40 ... +80 °C
process pressure -0,2 ... +2 bar
(-20 ... +200 kPa)
The VEGASON 63
integrated ultrasonic sensor for continuous level measurement is
suitable for measuring liquid or solid media in various industrial fields.
Advantages
- UP material probe with stainless steel 316L diaphragm and integrated temperature sensor for calibrating the running time of sound waves
- Accuracy ±10 mm
- ECHOFOX - Signal analysis processing with advanced fuzzy logic
- Via PLICSCOM, HART- Programmer or computer commissioning
- belongs to the plics product range
Measuring range Liquid: 0.6 ... 15 m
solid: 0.6 ... 7 m
process connection locking flange or universal joint
process temperature -40 ... +80 °C
process pressure -0,2 ... +1 bar
(-20 ... +100 kPa)
The VEGASON 64
ultrasonic sensor for continuous level measurement is
suitable for measuring solid media. The optional universal joint is used to adapt to the shape of the container and the angle of the medium.
Advantages
- UP material probe with stainless steel 316L diaphragm and integrated temperature sensor for calibrating the running time of sound waves
- Accuracy ±10 mm
- ECHOFOX - Signal analysis processing with advanced fuzzy logic
- Via PLICSCOM, HART- Programmer or computer commissioning
- belongs to the plics product range
Measuring range Liquid: 1... 25 m
solid: 1 ... 15 m
process connection flange, optional with universal joint
process temperature -40 ... +80 °C
process pressure -0,2 ... +0.5 bar
(-20 ... +50 kPa)
The VEGASON 65
ultrasonic sensor for continuous level measurement is
suitable for measuring solid media. The optional universal joint is used to adapt to the shape of the container and the corner of the medium.
Advantages
- UP material probe with aluminum diaphragm and PE foam rubber coating, and integrated temperature sensor for calibrating the running time of sound waves
- Accuracy ±10 mm
- ECHOFOX - Signal analysis processing, using advanced Fuzzy logic
- via PLICSCOM, HART-programmer or computer commissioning
- belongs to the plics product range
Measuring range Liquid: 0.8 ... 45 m
solid: 0.8 ... 25 m
process connection flange connection, optional with universal joint
process temperature -40 ... + 80 °C
process pressure -0,2 ... +0.5 bar
(-20 ... +50 kPa)
Process automation control and on-site inspection instrument one-stop supply platform
180-7313-9090
as a partner of many well-known brands, we will guarantee your employees' occupational health, safe environment and bright future with excellent quality and service!
Introduction
● tilt switch vertically suspended in external force is applied, when more than 15 degrees from vertical, the water inside the switch silver contact operation, the normally closed contacts open. When the external force is removed, the tilt switch returns to the vertical state, and the mercury contact is closed again. Engaged by the inclined contact opening is determined to change the switching operation of the protection device, to take timely measures to be applied, to achieve the purpose of security.
● Be careful when installing the product using a rope or chain hanging cable must be used to maintain a relaxed state, or affect the production of goods movement.
Application range
● Chute or transfer blockage detection
● Conveyor belt deviation detection
● Dumper unloading detection
● Used for belt or vibrating feeders with or without material detection
Features
Rugged, corrosion resistant, easy to install, and the control unit is a printed circuit board structure.Adjustable delay to prevent malfunction.
Standard Housing Type 20-43-\ExtAlx Type 20-38-Class II All mounting probes are equipped with mounting accessories. Its performance has been