| Electrical technical indicators | 
					| Current measurement: dc and ac, 10 Hz to 100 Hz | 															| Range :  40A | Resolution :  10 mA Class A Accuracy :  1.5 % Reading + 15 digits
 Inrush Current Trigger Level :  0.50 A Trigger Level of
 Frequency Filter Off :  2.50 A Trigger Level of
 Frequency Filter On :  0.50 A
 |  						| Range :  400A | Resolution :  100 mA Class A Accuracy :  1.5 % Reading + 5 digits
 Inrush Current Trigger Level :  5.0 A
 Frequency Filter Off Trigger Level :  2.5 A
 Frequency Filter On Trigger Level :  2.5 A
 |  						| Range :  2000 A; 1400 ac rms | Resolution :  1 A Class A Accuracy :  1.5 % Reading + 5 digits
 Inrush Current Trigger Level :  5 A Trigger Level of
 Frequency Filter Off :  8 A Trigger Level of
 Frequency Filter On :  8 A
 |  | 
					| Crest factor (50/60 Hz) | 															| Range :  40A | Crest factor * :  2 @ 33 A, 2.4 @ 27 A |  						| Range :  400A | Peak Factor* :  2 @ 330 A, 2.4 @ 270 A |  						| Range :  2000 A; 1400 ac rms | Crest factor * :  2 @ 1000 A, 2.4 @ 833 A |  | 
					| Current measurement :  ac, 100.1 Hz to 1 kHz | 															| Range :  40A | Resolution :  10 mA Accuracy > 10 A :  3.5 % Reading + 15 digits
 Inrush Current Trigger Level :  0.50 A Trigger Level of
 Frequency Filter Off :  2.50 A Trigger Level of
 Frequency Filter On :  0.50 A
 |  						| Range :  400A | Resolution :  100 mA Accuracy > 10 A :  3.5 % Reading + 5-digit
 Inrush Current Trigger Level :  5.0 A
 Frequency Filter Off Trigger Level :  2.5 A
 Frequency Filter On Trigger Level :  2.5 A
 |  						| Range :  2000 A; 1400 ac rms | Resolution :  1 mA Accuracy > 10 A :  3.5 % Reading + 5-digit
 Inrush Current Trigger Level :  5 A Trigger Level of
 Frequency Filter Off :  8 A Trigger Level of
 Frequency Filter On :  8 A
 |  | 
					| Voltage measurement : (type 355 only) dc and ac, 10 Hz to 100 Hz (600 V and 1000 V range over 10 %, up to 660 V and 1100 V respectively)
 | 															| Range :  4 V | Resolution :  1 mV Accuracy :  1 % Reading + 10-bit digital
 frequency filter off trigger level :  0.050 V
 frequency filter on trigger level :  0.050 V
 |  						| Range :  40 V | Resolution :  10 mV Accuracy :  1 % Reading + 5-bit digital
 frequency filter off trigger level :  0.25 V
 frequency filter on trigger level :  0.25 V
 |  						| Range :  400 V | Resolution :  100 mV Accuracy :  1 % Reading + 5-bit digital
 frequency filter off trigger level :  6 V
 frequency filter on trigger level :  6 V
 |  						| Range :  600 V ac rms | Resolution :  1 mV Accuracy :  1 % Reading + 5-bit digital
 frequency filter off trigger level :  6 V
 frequency filter on trigger level :  6 V
 |  						| Range :  1000 V dc | Resolution :  1 V Accuracy :  1 % reading + 5 digits
 |  | 
					| Voltage measurement : (type 355 only) ac, 100.1 Hz to 1 Hz (600 V and 1000 V range over 10 %, up to 660 V and 1100 V respectively)
 | 															| Range :  4 V | Resolution :  1 mV Accuracy :  3 % Reading + 10-bit digital
 frequency filter off trigger level :  0.050 V
 frequency filter on trigger level :  0.050 V
 |  						| Range :  40 V | Resolution :  10 mV Accuracy :  3 % Reading + 5-bit digital
 frequency filter off trigger level :  0.25 V
 frequency filter on trigger level :  0.25 V
 |  						| Range :  400 V | Resolution :  100 mV Accuracy :  3 % Reading + 5-bit digital
 frequency filter off trigger level :  6 V
 frequency filter on trigger level :  6 V
 |  						| Range :  600 V ac rms | Resolution :  1 V Accuracy :  3 % Reading + 5-bit digital
 frequency filter off trigger level :  6 V
 frequency filter on trigger level :  6 V
 |  | 
					| Resistance measurement (type 355 only) | 															| Range :  400 Ω | Resolution :  0.1 Ω Accuracy :  1.5 % + 5 digits
 |  						| Range :  4 kΩ | Resolution :  1 Ω Accuracy :  1.5 % + 5 digits
 |  						| Range :  40 kΩ | Resolution :  10 Ω Accuracy :  1.5 % + 5 digits
 |  						| Range :  400 kΩ | Resolution :  100 Ω Accuracy :  1.5 % + 5 digits
 |  | 
					| On-off buzzer (type 355 only) |  | 
					| Measuring frequency | 															| Measuring range | 5.0 Hz to 1 kHz |  						| Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |  						| Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 digits |  						| Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 digits |  						| Trigger level | Reference current and voltmeter |  |