- Brand: ZEMIC
- Series: Packaging Machine Sensors
- Model: L6D-C3-10kg
- Color classification: 2.5kg 3kg 5kg 6kg 10kg 15kg 8kg 20kg 30kg 40kg 50kg





◆L6D load cell can meet the measurement in the range of 2.5kg-50kg.
◆Silicone rubber seal, anodized surface, good anti-corrosion performance.
◆Applicable to all kinds of electronic weighing equipment such as electronic pricing scales, electronic platform scales, etc.
Recommended model selection:
| 2.5kg-50kg | Cx | L6D-Cx-xxkg-0.4B |
Technical indicators
| Rated load | kg | 2.5/3/5/6/8/10/15/20/25/30/35/40/50 |
| Output sensitivity | mv/v | 2.0±0.2 |
| precision | | C3 | C4 | C5 |
| Comprehensive error | %FS | ±0.02 | ±0.015 | ±0.01 |
| Creep/Zero | %FS/2min | ±0.0167 | ±0.0125 | ±0.01 |
| The effect of temperature on output sensitivity | %FS/10℃ | ±0.0175 | ±0.0131 | ±0.01 |
| The effect of temperature on zero output | %FS/10℃ | ±0.02 | ±0.012 | ±0.009 |
| Zero output | %FS | ±2 |
| Temperature Compensation Range | °C | -10~+40 |
| allowable temperature range | °C | -35~+65 |
| input resistance | Ω | 406±6 |
| output impedance | Ω | 350±3 |
| Insulation resistance | MΩ | ≥5000(50VDC) |
| Recommended excitation voltage | V | 5~12(DC) |
| Maximum excitation voltage | V | 18(DC) |
| Safe overload range | %FS | 120 |
| Limit overload range | %FS | 150 |
| Protection class | | IP65 |
| Cable Specifications | mm | 3.8 |
| cable length | m | 0.4 |
| Recommended Weighing Platform Size | mm | 250x350 |
| Four corner errors | | 0.02% load value/100mm |
| Recommended Mounting Torque | Nm | 2.5kg-25kg: 6; 30kg-50kg: 10 |
Dimensions mm (inch)