P SWP-LEDSeries Instrument Introduction
SWP-LEDThe series of intelligent instruments are the latest generation of intelligent instruments developed by our company based on our years of experience in manufacturing digital instruments, extensive research on advanced foreign products, and combining the characteristics of Chinese industrial field applications.
SWP-LEDThe series of intelligent instruments adopt a number of advanced technologies, which greatly improves the stability and reliability of operation.
SWP-LEDThe appearance and structure of the series of intelligent instruments have been greatly improved on the original basis, bringing greater convenience to users' installation and maintenance.
SWP-LEDAs detection and control products in industrial process automation systems, the series of intelligent instruments are widely used in defense, steel, electric power, petrochemical, machinery, pharmaceuticals, textiles, metallurgy, printing and dyeing and other industries.
SWP-LEDSeries Instrument Features
1, using a more integrated ICChips and advanced SMTThe surface component mounting process and unique circuit shielding technology give the instrument super anti-interference ability and reliability, and it can work stably for a long time in an electromagnetic interference environment.
2, the universal input jumper setting is adopted, so that each instrument can realize the input of various instrument graduation numbers, standard signals, remote pressure signals, and millivolt signals through simple and quick parameter setting.
3, adopting a modular universal circuit structure, various functional changes of the instrument can be realized through simple module combination, and the versatility and flexibility are significantly enhanced.
4, It adopts microcomputer-controlled fully automatic digital adjustment system, and no potentiometer adjustment is required.
5The instrument has a beautiful and elegant appearance and comes in a variety of shapes, structures and sizes.
6The whole machine and movement assembly adopt a snap-in structure, which makes maintenance and assembly and disassembly very easy.
7, Power supply can be selected: AC 220V, 50/60HZ, 90~ 265VSwitching power supply, or DC 24Vpower supply.
8, can be equipped with RS-232/RS-485or RS-422Communication interface, convenient for connecting with host computer to form control system.
SWP-LEDseriesThe digital display controller/light column display controller adopts a microprocessor for control calculation and can perform highly accurate linear correction measurement on various nonlinear input signals.
SWP-LEDseriesThe light column display controller integrates digital instruments and analog instruments. It can perform digital display control (high-brightness LED digital display) and relative analog display (light column display) of measurement signals such as temperature, pressure, liquid level, speed, etc., making the display of measurement values clearer and more intuitive. Dual light column display mode can be selected..
Selection Table
model | Code | illustrate | SWP - | □ □ □ □ - □ □-□□-□ □ -□ □ | New Series | Appearance characteristics | | | | | | | | | | | Horizontal display instrument | Vertical display instrument | | Dimensions | | | | | | | | | | 48×48mm | 96×48mm (horizontal), 48×96mm (vertical) | 72×72mm | 160×80mm (horizontal), 80×160mm (style) | 96×96mm | | Control effect | | | | | | | | | Measurement display | Three-position control | Four-limit control or four-limit alarm output | | Communication | □ | | | | | | | See "Communication Methods" | Output method | □ | | | | | | Refer to "Transmission output mode" | Input Type | □□ | | | | | See "Input Type" | First alarm mode | | | | | No alarm (can be omitted) | Upper limit control/alarm (four limit control/alarm 2H) | Lower limit control/alarm (four limit control/alarm 2L) | | Second alarm mode | | | | No alarm (can be omitted) | Upper limit control/alarm (four limit control/alarm 2H) | Lower limit control/alarm (four limit control/alarm 2L) | | Feed output | P | | DC24V power supply output | Power supply | | DC24V power supply | AC90~265V power supply (switching power supply) | AC220V power supply (linear power supply, can be omitted) | | |
|
★ Input type |
Code | Input Type | Measuring range | Code | Input Type | Measuring range | Code | Input Type | Measuring range | 01 | B | 400~1800 ℃ | 09 | Pt100.1 | -99.9~199.9℃ | 17 | 30~350Ω | -1999~99999 d | 02 | S | 0 ~1600 ℃ | 10 | Cu50 | -50.0~150.0℃ | 18 | Special specifications | User Specific | 03 | K | 0 ~1300 ℃ | 11 | Cu100 | -50.0~150.0℃ | 19 | 4~20 mA square root | -1999~99999 d | 04 | E | 0 ~ 1000 ℃ | 12 | 4~20mA | -1999~99999 d | 20 | 0~10mA square root | -1999~99999 d | 05 | T | -200~400 ℃ | 13 | 0~10mA | -1999~99999 d | twenty one | 1~ 5 V square root | -1999~99999 d | 06 | J | 0 ~1200 ℃ | 14 | 1~5 V | -1999~99999 d | twenty two | 0~5 V square root | -1999~99999 d | 07 | Wre | 0 ~ 2300 ℃ | 15 | 0~5 V | -1999~99999 d | twenty three | Switchable input | See the table below for details | 08 | Pt100 | -200~650℃ | 16 | 0~20mA | -1999~99999 d | twenty four | Frequency input | 0~5kHz | |
★ Full switch input: You only need to set the secondary parameters of the instrument to switch to input multiple graduation numbers. The graduation numbers that can be input are as follows: |
Code | Input Type | Code | Input Type | Code | Input Type | Code | Input Type | Code | Input Type | 01 | B | 05 | T | 09 | Pt100.1 | 14 | 1~5 V | 18 | 1~ 5V square root | 02 | S | 06 | J | 10 | Cu50 | 15 | 0~5 V | 19 | 0~5V square root | 03 | K | 07 | Wl | 12 | 4~20mA | 16 | 4~20 mA square root | | | 04 | E | 08 | Pt100 | 13 | 0~10mA | 17 | 0~10mA square root | | | |
★ Transmission output mode |
Selection code | 0 | 2 | 3 | 4 | 5 | 8 | Output method | No output | 4~20mA | 0~10mA | 1~5V | 0~5V | Special specifications | |
★ Communication method |
Selection code | 0 | 2 | 4 | 8 | 9 | Communication | No communication | RS-232 | RS-422 | RS-485 | Special specifications | |
★ Note 1: C80 series is 0.8-inch LED display, C90, S80, C70, C40 series is 0.56-inch LED display, C10 series is 0.32-inch LED display. |
★ Note 2: Four-limit control or four-limit alarm outputs are four relay control outputs. Users can modify the internal parameters to set the required control or alarm mode. (Four-limit control/alarm is only available for T.C80, S80 and C90 series. 2H represents two upper limit control/alarms, and 2L represents two lower limit control/alarms). |
★ For the same graduation number, the selection code and instrument programming code are different. Please pay attention when setting the instrument. |
★ Note 3: C70 and C10 have no frequency signal input. |
★ Model example: |
SWP-C803-21-08-HL-T |
The measurement shows that the communication method is RS232, the output method is relay output, the input type is PT100, the first alarm is the upper limit alarm, the second alarm is the lower limit alarm, and the power supply is AC90~260V. |
C101/401/701/901/801-00-12(23)-N |
C101/401/701/901/801-00-12(23)-NP |
C101/401/701/901/801-02-12(23)-N |
C101/401/701/901/801-02-12(23)-NP |
C101/401/701/901/801-80-12(23)-N |
C101/401/701/901/801-80-12(23)-NP |
C101/401/701/901/801-82-12(23)-N |
C101/401/701/901/801-82-12(23)-NP |