Working power supply | AC85 ~ 265V (50/60Hz) or DC18 ~ 36V optional Power about 8W |
Weighing process | AD sampling method: Delta-Sigma method AD sampling rate: 100 times / second Internal resolution: 1/260000 Display resolution: 1/50000( ) Nonlinearity: 0.005%FS |
Weighing interface | Input sensitivity: ≥ 0.25uV/d Input signal range: - 30.5 ~ 30.5mV Zero signal range: - 30.5 ~ 30.5mV Sensor excitation voltage: 10V &lusmn; 1% Driving capacity: can drive up to 4 350 Ω sensors |
Switching interface | Enter 2 , both can be customized |
communication | PROFIBUS DP interface PLC update rate: 40 times / second Communication baud rate: 9.6k , 19.2k , 45.45k , 93.75k , 187.5k , 500k , 1.5M , 3M , 6M , 12M ( adaptive ) |
other | Installation method: panel installation ( protection level: IP65) Weight: about 0.65kg Operating environment temperature: -10 ~ 45 ℃ Relative humidity: 10 ~ 90% , no condensation Display: 6 -digit high-brightness red digital tube ( character height 13mm) Indicator lights : 5 Buttons : 6 |
Features
● Support PROFIBUS DP bus interface, communication baud rate 9.6k~12M, baud rate adaptive
● High display resolution, display resolution 1/50000
● 2AI/AO or 4AI/AO optional, main function: real-time mapping of weight and status data to the PLC data area; PLC can command to control the instrument to achieve operations such as clearing and calibration
● Rich instruction error instructions
Application scope
Connection diagram
Working power supply | DC18 ~36V standard configuration AC85 ~265V(50/60Hz) , Optional power is about 8W |
Weighing process | AD sampling method: Delta-Sigma method AD sampling rate: 100 times / second Internal resolution: 1/260000 Display resolution: 1/50000( ) Nonlinearity: 0.005%FS |
Weighing interface | Input sensitivity: ≥ 0.25uV/d Input signal range: - 30.5 ~ 30.5mV Zero signal range: - 30.5 ~ 30.5mV Sensor excitation voltage: 10V &lusmn; 1% Driving capacity: can drive up to 4 350 Ω sensors |
Switching interface | Enter 2 , both can be customized |
communication | CC-Link interface PLC update rate: 40 times / second Communication baud rate: 156K, 625K, 2.5M, 5M, 10M |
other | Installation method: panel installation ( protection level: IP65) Weight: about 0.65kg Operating environment temperature: -10 ~ 45 ℃ Relative humidity: 10 ~ 90% , no condensation Display: 6 -digit high-brightness red digital tube ( character height 13mm) Indicator lights : 5 Buttons : 6 |
Features
●Support CC-Link bus interface
● High display resolution, display resolution 1/50000
● Provides 4AI/AO options, main functions: real-time mapping of weight and status data to the PLC data area; PLC can command and control the instrument to achieve operations such as clearing and calibration
● Rich instruction error instructions
Application scope
Connection diagram
Working power supply | DC18 ~36V standard configuration AC85 ~265V(50/60Hz) , Optional power is about 8W |
Weighing process | AD sampling method: Delta-Sigma method AD sampling rate: 100 times / second Internal resolution: 1/260000 Display resolution: 1/50000( ) Nonlinearity: 0.005%FS |
Weighing interface | Input sensitivity: ≥ 0.25uV/d Input signal range: - 30.5 ~ 30.5mV Zero signal range: - 30.5 ~ 30.5mV Sensor excitation voltage: 10V &lusmn; 1% Driving capacity: can drive up to 4 350 Ω sensors |
Switching interface | Enter 2 , both can be customized |
communication | Modbus TCP protocol PLC update rate: 40 times / second Communication baud rate: 10M/100M adaptive |
other | Installation method: panel installation ( protection level: IP65) Weight: about 0.65kg Operating environment temperature: -10 ~ 45 ℃ Relative humidity: 10 ~ 90% , no condensation Display: 6 -digit high-brightness red digital tube ( character height 13mm) Indicator lights : 5 Buttons : 6 |
Features
●Support Modbus TCP protocol
● High display resolution, display resolution 1/50000
● Provide 4AI/AO, main functions: real-time mapping of weight and status data to the PLC data area; PLC can command to control the instrument to achieve operations such as clearing and calibration
● Rich instruction error instructions
Application scope