MQM4 series AC analog traction electromagnet is a mechatronics product developed and developed by our company. This product adopts a new design, and uses the direct electromagnet to simulate the running curve of the AC electromagnet with the combination of traditional electromagnet theory and modern electronic technology. Because the operation of the common AC traction electromagnet is a function of the air gap, that is, the operating current is determined by the size of the air gap, which causes the disadvantage that the ordinary AC electromagnet cannot work under overload conditions. The working current of the AC analog traction electromagnet is a function of the amount of motion of the armature per unit time, that is, the working current is completely determined by the armature motion state, so it has good overload characteristics. The product has the advantages of stable operation, no noise and good overload performance of the DC electromagnet, and has the advantages of large traction force of the AC electromagnet, simple control and long stroke. The circuit module with intelligent function overcomes the shortcomings of overloading and burning of the AC electromagnet. During the use, if the armature is stuck for various reasons, under the control of the module, the electromagnet automatically switches to the working state to ensure its long-term reliable operation. Another function of the intelligent circuit module is to automatically adjust the input electric energy according to the weight of the load during the operation of the electromagnet, and the energy saving effect is obviously superior to that of the ordinary electromagnet. MQM4-25-80 AC analog traction electromagnet is used in rotary cement packaging machines, punching machines, shearing machines, lifting, metallurgy, mining, construction machinery and automation systems for remote operation of traction control devices. First, the model meaning |
| □: Meaning F: Jog operation, no hold function Y: Controller split installation K: With computer interface A: Derived product W: Indicates maintainable | |
Second, technical parameters Product number | Rated voltage V | Rated stroke mm | Rated suction N | Operating frequency / hour | Starting current A | MQM4-25-50 | 220 | 25 | 50 | 600 | 2 | MQM4-25-50 | 380 | 25 | 50 | 600 | 1.3 | MQM4-25-80 | 220 | 25 | 80 | 600 | 5 | MQM4-25-80 | 380 | 25 | 80 | 600 | 3 | MQM4-25-150 | 220 | 25 | 150 | 300 | 8 | MQM4-25-150 | 380 | 25 | 150 | 300 | 5 | Third, the shape and installation size 1, shape 2, installation size Model | A | B | D1 | D2 | D3 | H1 | H2 | H3 | MQM4-25-050 | 70 | 52 | 20/25 | 56 | 6 | 117 | 112 | 95 | MQM4-25-080 | 83 | 62 | 24/33 | 68 | 8 | 135 | 125 | 105 | MQM4-25-080A | 83 | 62 | 24/33 | 68 | 8 | 122 | 112 | 92 | MQM4-25-150 | 110 | 84 | 40/48 | 92 | 8 | 175 | 162 | 135 | |
4. Normal working conditions and installation conditions 1. Ambient air temperature a) The upper limit of ambient air temperature does not exceed +40 °C; b) The average value of ambient air temperature within 24 h does not exceed +35 °C; c) The lower limit of ambient air temperature is not lower than - 15 ° C. 2. The altitude of the installation site should not exceed 3000m. 3. The relative humidity of the atmosphere does not exceed 50% when the ambient air temperature is +40 °C. 4. Installation conditions a) The product can be installed in any direction in principle, and the direction of the reaction must be coincident with the axis of the armature. The deviation should not exceed ±15° b) The longest service life when installing the electromagnet in the vertical direction (when the armature is up When moving, the suction of the electromagnet should include the weight of the armature). c) installed in places where there is no severe shaking and impact; d) installed in a medium without explosion hazard, and there is no gas and dust (including conductive dust) in the medium that is sufficient to corrode metal and damage insulation; e) installed in no rain or snow The place of invasion. V. Instructions for ordering 1. The suction force of the selected electromagnet should be similar to the reaction force of the electromagnet by the use mechanism. It should not be too disparate, otherwise the mechanical life of the electromagnet will be reduced. 3. The electromagnet should be placed in a warehouse where the air is circulated and the temperature is not higher than +40 ° C and not lower than -5 ° C. 4. When installing the electromagnet, it should be noted that the reaction force of the mechanism connected to the electromagnet must coincide with the center line of the armature. Otherwise, noise will occur, and the coil will be burned even due to friction and overheating of the armature. 5. The electromagnet can reliably pull in when the power supply voltage is ≥85% of rated value and the stroke is rated. |