Product Model : MT-10K-D
Dimensions : 160*160*80(mm) length *width* height
Power supply voltage : AC220V/50~60Hz±10%
Output voltage : DC24V
Node type : non - contact
Output indication : 6- digit LED
Adjustment method : button type
Maximum output points: 1-10 points
Working mode : single pulse /online
Parameter setting of four-button controller: Press the on/off key to run or stop the controller. When setting parameters, first press the on/off key to display OFF or directly press the setting key , then press the setting key and the first two digital tubes will flash, press the plus/minus keys to set the output path parameters. Press the setting key again and the pulse width light will light up, press the plus/minus keys to set the pulse width parameters. Press the setting key again and the pulse interval light will light up, press the plus/minus keys to set the pulse interval parameters. Press the setting key again and the cycle interval light will light up, press the plus/minus keys to set the cycle interval parameters. Press the setting key again to complete the parameter setting. Press the on/off key to run the controller.
Parameter code | Parameter Number/Name | | Setting range (F) | | unit | Remark |
1 | Number of channels setting | | 1 ~44 | | | According to each model |
2 | Pulse Width | | 0.05-9.9 points | | 0.1 seconds | According to each model |
3 | Pulse interval | | 2 seconds - 30 minutes | | 1 second | According to each model |
4 | Cycle Interval | | 2 seconds - 30 minutes | | 1 second | According to each model |