2. Structural characteristics
The shell is formed by casting, which is small in size and light in weight. The operation lever is flexible and reliable. Metal parts are treated with anti-rust and anti-corrosion treatment, and fasteners have measures to prevent automatic loosening.
3. Technical parameters
1. Action stroke: 15mm Tolerance: ±3mm
2. Action force: 50~100N
3. Reset force: 40~80N
4. Contact resistance: The contact resistance of the closed contact is not greater than 0.1Ω.
5. Action performance: The switch acts and locks immediately after being acted by the action force, and can only be unlocked after manual reset.
6. Contact capacity: DC12V/0.5A
7. Dimensions: 156mm×91mm×181mm
8. Weight: 2kg
1. Purpose and scope of application:
khj0.5/12 mine intrinsically safe emergency stop switch (hereinafter referred to as emergency stop switch) is suitable for underground coal mines containing explosive gas (ch4) environment and open-pit coal mines, coal preparation plants and other workplaces, as a mining belt conveyor It is used to detect the emergency stop signal of the integrated protection and control device of the machine.
2. Main technical features:
1. Explosion-proof type: mine intrinsically safe type, explosion-proof mark: exibi;
2. Model meaning:
k ----- switch
h ----- Intrinsically safe
j ----- emergency stop
0.5/12- Contact capacity
3. Executive standards: mt/t 647-1997, q/hwt92-2007;
4. Contact capacity 12v/0.5a;
5. Contact resistance ≤ 0.1ω, after vibration and impact ≤ 0.2ω;
6. Action performance: When a force of 40n~200n is applied outward on the pull ring on either side of the emergency stop switch, the contact state in the emergency stop switch should be reversed and self-locked; apply 40n outward on the corresponding reset pull ring When the force of ~200n is applied, the contact state in the emergency stop switch should be restored.
7. Dimensions: 380mm×170mm×72mm;
8. Mass: 3kg.
3. Environmental conditions:
(1) Normal working conditions:
1. The ambient temperature is -5℃~+40℃;
2. The altitude does not exceed 2000m (air pressure 86kpa ~ 110kpa);
3. The relative humidity of the surrounding air is less than or equal to 98%rh (25℃);
4. In mines containing explosive gases such as methane;
5. There is no significant shaking and shock vibration;
6. In an environment without gas or vapor that destroys insulation;
7. A place that can prevent dripping water.
(2) Bad storage and transportation conditions:
1. High temperature: 60℃;
2. Low temperature: -40℃;
3. Average relative humidity: 95% (25℃).
Fourth, the structure overview:
Emergency stop switch consists of shell, travel switch, emergency stop pull ring, reset pull ring, wiring terminal and other parts.
5. Working principle:
When a force of 40n~200n is applied to the emergency stop pull ring on either side of the emergency stop switch and a displacement occurs, the travel switch in the emergency stop switch acts, the contact state is reversed, and self-locking; When an external force of 40n~200n is applied, the limit switch in the emergency stop switch operates again, and the contact state is restored.