1 . 2 Composition and representational models
1 . 3 Explosion-proof type is : Mine intrinsically safe explosion-proof mark: ExibI
. 1 . . 4 Environmental conditions
. 1 . . 4 . . 1 meandering sensor should be able to work in the following conditions:
a. The ambient temperature is -20~+40 ℃;
b. Average relative humidity: not more than 95% ( 25 ℃);
c. Atmospheric pressure is 80 ~ 106kPa ;
e. Vibration: acceleration 50m/s 2 ;
f. Shock: peak acceleration 500 m/s 2 ;
g. There is no corrosive gas that destroys insulation in coal mines;
h. Used in hazardous locations with explosive mixtures such as methane, coal dust, etc.;
. 1 . . 4 . 2 of the worst weather conditions Storage meandering sensor is able to withstand:
- temperature: +60 deg.] C;
- low temperature: -40 ℃;
- Average relative humidity: 95% ( +25 °C).
2 Structural features and working principle
2 . . 1 Structure:
Small size, light weight, good sealing performance and easy maintenance; after the contact action, there is still a large rotation buffer angle of the probe rod, so that it is not easily damaged; the probe rod is equipped with a rolling sheath to avoid friction between the probe rod and the tape .
2 . 2 works
When the tape is running normally, the probe rod of the deflection switch is in the vertical position. When the tape deviates, the tape touches the probe rod of the deviation switch and drives the shaft of the probe rod to rotate. When the probe rod is deflected to a certain angle, the travel switch in the deviation switch is toggled to issue a deviation signal.
3 main performance
. 3 . . 1 contact capacity: DC12V / 0.5A ; intrinsically safe circuits passed the test used in;
. 3 . 2 output contact in the form of: a pair of normally open
3.3 Weight: 3kg
. 3 . . 4 Dimensions: 380mm × 170mm × 72mm
. 3 . . 5 operating angle: 30o ± 3o
3.6 Action force of contact rod: 20N ~ 100N
3.7 Reset angle: 15 °±3°
3.8 Limit angle of probe rod rotation: ≥70°
3.9 Enclosure protection grade: IP54
4 Installation and use
4.1 Installation
Install the deviation sensor on the frame of the belt conveyor, and pay attention to adjust the position of the probe rod of the deviation sensor and the tape.
4.2 Wiring
Users can choose mine rubber sheathed cable 3×1.5 with an outer diameter of 6 ~ 12mm according to their needs , and lead the output contact of the deviation sensor to the main control contact of the coal mine belt conveyor protection device.
4.3 Notes
4.3.1 The power supply used conforms to the rated voltage on the nameplate.
4.3.2 Warning words
a . It can only be connected to the intrinsically safe circuit that has passed the anti-riot joint inspection.
b. The power supply used and the rated voltage on the nameplate conform to
5 random files
Packing list, product certificate and instruction manual