Công ty TNHH công nghệ số Tân Thành

Đồng hồ hiệu chuẩn áp suất, victor Victory instrument pressure calibrator vc15+

  • Đăng ngày 19-11-2019 07:10:15 PM - 1427 Lượt xem
  • Mã sản phẩm: vc15+
  • Đồng hồ hiệu chuẩn áp suất, victor Victory instrument pressure calibrator  vc15+ 


    Tình trạng sản phẩm:


    Basic Features:

              Measurement and output accuracy is 0.02%, measurement is displayed as 5 digits, and output is displayed as 6 digits.

    Measurement function:

    DC voltage, DC current, frequency, on-off measurement, pressure

    Output function:

    DC voltage, DC current, analog transmitter, frequency, number of pulses, pressure

              Internal 24 V loop power supply to power the transmitter and simultaneous milliamp measurements

              Fast-responding switch test allows capture switch settings, resets, etc.

              25% and 100% manual stepping, automatic stepping and automatic ramp output for DC current output

              Large-screen LCD multi-data display, can display simultaneously: DC current and % value

              It can be equipped with 43 pressure modules of different pressure ranges of APM series, which can display 5-digit pressure measurement with accuracy of 0.025%

              It has the function of automatic pressure zero adjustment; it has the function of testing the switch. It automatically locks the current pressure display value and the on/off state of the switch when the switch is off-pass or on-off.

              The operation performance is superior to the keyboard configuration, and the increase/decrease key of the output setting corresponds to the display setting value on the LCD.

              Panel calibration technology allows calibration without opening the case

              With white LED backlight, with automatic backlight off and automatic power off function, suitable for field use

    Measurement basic technical specifications [ applicable withinone year after calibration, 23 °C ± 5 °C, 35 ~ 70% RH, accuracy = ± (% of reading + range %)]    

    Measurement function

    Range

    Measuring range

    Resolution

    Accuracy

    Remarks

    DC voltage

    DCV

    200mV

    -20.00 to 220.00mV

    10μV

    0.02+0.02

    Input resistance:

    About 100MΩ

    5V

    -0.5000 to 5.5000V

    0.1mV

    0.02+0.01

    Input resistance: about 1MΩ

    50V

    -5.000 to 55.000V

    1mV

    0.02+0.01

    DC

    DCI

    50mA

    -4.000 to 55.000 mA

    1μA

    0.02+0.01

    Input impedance: 5Ω

    frequency

    FREQ

    500Hz

    3Hz ~ 500.00Hz

    0.01Hz

    ±2 words

    Input impedance: greater than 100kΩ

    Frequency sensitivity:

    Square wave at least 3Vp-p

    50% duty cycle

    5KHz

    3Hz ~ 5.0000KHz

    0.1Hz

    50KHz

    3Hz ~ 50.000KHz

    1Hz

    On-off detection

    ≤250Ω sound

    OPEN/CLOSE

     

     

    Open circuit voltage is about 2.5V

    Other features :

       Measurement rate: 2 times / sec

       DCV measurement

                 Common mode rejection: 50Hz / 60Hz > 120dB

    Series mode suppression: 50Hz / 60Hz > 60dB

       Temperature coefficient: 0.1 * (specified accuracy) % /  °C (temperature range 5~18°C or 28~50°C)   

       Maximum voltage applied between input terminals and ground: 60Vp-p

    mA terminal maximum current: 55mA

    mA terminal input protection: 60mA/250V fast melting

     

    Output basic technical specifications [ applicable withinone year after calibration, 23 °C ± 5 °C, 35 to 70% RH, accuracy = ± (set value % + range %)]      

    Features

    Range

    Output setting range

    Resolution

    Accuracy

    Remarks

    DC voltage

    DCV

    1000mV

    -100.00 ~ 1100.00mV

    10μV

    0.02+0.01

    Maximum output current 2mA

    10V

    -1.0000 to 11.0000V

    0.1mV

    0.02+0.01

    Maximum output current 5mA

    DC

    DCmA

    20mA

    0.000 to 22.000 mA

    1μA

    0.02+0.02

    At 20 mA,

    Maximum load 1KΩ resistor

    When simulating the transmitter,

    External power supply 5~28V

    Maximum load 1KΩ resistor

    frequency

    FREQ        

    100Hz

    1.00Hz to 110.00Hz

    0.01Hz

    ±2 words

    to 11 Vp-p square wave

    Level accuracy

    ±10 % reading +0.5V

    50% duty cycle

    Load >100KΩ

    1KHz

    0.100KHz ~ 1.100KHz

    1Hz

    10KHz

    1.0KHz ~ 11.0KHz

    0.1KHz

    pulse

    PULSE

    100Hz

    to 100000cycles

    1cyc

    ——

    to 11 Vp-p square wave

    Level accuracy

    ±10 % reading +0.5V

    50% duty cycle

    Load >100KΩ

    1KHz

    10KHz

    Loop power

    LOOP

    24V

     

     

     

    Maximum output current 25mA

    Short circuit protection

          

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

     

    Other features:

              Temperature coefficient: 0.1 * (specified accuracy) / °C (temperature range 5~18°C or 28~50°C)  

              Maximum voltage applied between output terminals and ground: 30VDC

           Maximum output current: 25mA

     

    Basic technical indicators

     

    pressure

    PRESS

    Depending on the pressure module

    ——

    Depending on the pressure module

    Depending on the pressure module

    It can be equipped with 43 kinds of pressure modules of APM series, which provide modules for differential pressure, gauge pressure, vacuum pressure, absolute pressure, double pressure and high pressure. For detailed technical specifications, please refer to the relevant pressure module technical data.

     

     

     

    General characteristics

              Working temperature and humidity

    0 to 50oC, ≤80%RH  without condensation

    40 to 50oC, ≤70%RH.

              Storage temperature and humidity

           -25 to 60oC, ≤90%RH without condensation

              Display and backlight

    *  Segment LCD dual display

    *  White LED backlight

              power supply

    * 4 x 1.5 AAA alkaline battery powered

              * CA charger can charge Ni-Hi battery (optional)

             *   Automatic shutdown operation: can set the automatic shutdown time 0~60minutes

             *   Battery life in continuous use (relative to alkaline batteries):

              Size and weight

    205 × 95 × 42 (mm), about 500g

              annex

    Test pen, fuse

         

     



    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ:
    -------------------------------
    CÔNG TY TNHH THIẾT BỊ CÔNG NGHIỆP TTH
    Trụ sở: số 124 ngõ 79 Yên Hoà-Cầu giấy-HN
    Kinh doanh 1 : 0816.861.515
    Kinh doanh 2 : 0836.861.515
    Email: tthkinhdoanh@gmail.com
    Email: tthkinhdoanh01@gmail.com

  • Kết nối với chúng tôi