WS5000 electricity power transducer WS5000 series are widely used in single-phase, three-phase active power, reactive power converting DC voltage or DC current signal proportional to the measurement | | | | The main models are: single-phase active: WS5010 single-phase reactive: WS5110 single-phase apparent power: WS5210 three-phase active: WS5033 three-phase reactive: WS5133 three-phase apparent power: WS5233 characteristics: measurement input: rated input current 1 or . 5A; rated input voltage of 100 ~ 500V measurement output: DC voltage or DC current power supply: AC / DC common main technical parameters: input rated frequency: 50 ~ 60Hz rated input voltage: 100 ~ 500V rated input current: 1 ~ 5A correction Test coefficient: for active power 0.75~1.3; for reactive power 0.5~1.0 self-consumption: each current channel <0.1VA; each voltage channel UN×2mA overload capacity: voltage, current 1.2 times output terminal output voltage: 0~ 5V, 1~5V, 0~10V, 2~10V Output current: 0~20mA, 4~20mA, 0~10mA Load capacity: voltage ≥10KΩ, current 0~500Ω overload capacity: voltage <15V, current <23mA power terminal Working power: 24VDC, 220VAC working current: about 1.0W/4.5VA conversion capacity Response time: <300ms Accuracy: 0.2 or 0.5 Safety Insulation strength: 1500V/min Insulation resistance: >100MΩ Test voltage: 50Hz 1 minute 2500V input for all circuits and housing 2500V input circuit between 2500V power supply output and housing 2500V output to the housing Temperature coefficient: <150ppm / °C Operating temperature: -10 ~ 55 ° C Storage temperature: -40 ~ 70 °C Housing Material: Polycarbonate/ABS Housing Material Mounting: DIN T Rail Mounting | | Selection guide: Model specifications: single-phase active | WS5010 | | | | | | Single phase reactive | WS5110 | | | | | | Three-phase active | WS5033 | | | | | | Three reactive | WS5133 | | | | | | Input voltage: 100V | | 1 | | | | | 220V | | 2 | | | | | 380V | | 3 | | | | | User specified specification | | 6 | | | | | Input current: 1A | | | 1 | | | | 5A | | | 5 | | | | User specified specification | | | 6 | | | | Analog output: 4~20mA | | | | A | | | 0~20mA | | | | B | | | 0~5V | | | | C | | | 0~10V | | | | D | | | User specified specification | | | | 6 | | | Working power supply: 24VDC | | | | | H | | 110~220V | | | | | L | | Conversion accuracy: 0.2 | | | | | | 2 | Level 0.5 | | | | | | 5 | For example: WS5033-15A-L: The measurement mode is three-phase active; the input voltage is 100V; the input current is 5A; the analog output is 4~20mA; the working power is 110~220V; the conversion accuracy is the default 0.5. Dimensions: length 132 width 81 height 71 (mm) | | ![]() | | |