Công ty TNHH công nghệ số Tân Thành

Thiết bị chuyển đổi nhiệt độ, Siemens Temperature transmitter TH400 7NG3214-0NN00

  • Đăng ngày 25-04-2019 01:59:00 AM - 843 Lượt xem
  • Mã sản phẩm: TH400 7NG3214-0NN00
  • SITRANS TH400 
    fieldbus

    description
    SITRANS TH400 supports PROFIBUS PA or FF bus communication protocols. It is designed to support all common thermocouples, resistors and millivolt sensors. With SIMATIC PDM or AMS and Handheld Communicator (FF) , its setup is fast and simple. Because of its small dimensions, the device allows a flexible installation options even installed in a DIN standard B -type junction box.

    Tình trạng sản phẩm:


    Siemens temperature transmitter
    Top Mount Transmitter 
    SITRANS TH100 
    SITRANS TH200 
    SITRANS TH300 
    SITRANS TH400

    Rail Transmitter 
    SITRANS TR200 
    SITRANS TR300 
    SITRANS TW

    Field Transmitter 
    SITRANS TF 
    SITRANS TF280

    SITRANS TH100
     
    description
    SITRANS TH100 is designed for economical use. For example, electrical isolation is saved, which is not necessary for the Pt100 .The TH100 therefore provides economical operation and reliable measurements. It is an ideal replacement for the old analog PT100transmitter. With modem and SIPROM T software, its setup is quick and easy. This configuration tool is available for free download.
     
    Siemens temperature transmitter details
    Input PT100 resistor output 4 – 20 mA

    Characteristics
    ■  Measurement temperature is represented by a linear output signal
    ■  Provides high precision over the entire ambient temperature range
    ■  Reduce the impact of factory environmental noise
    ■ Alarm signal for open or short circuit of sensor  according to NAMUR 43
    ■ Explosion-proof standards for   US , Canada, and Europe
    ■  Compact design, ideal for upgrading PT100 sensors with a 4-20 mA signal installed
    ■  Sturdy design, fully filled electronics
     
    SITRANS TH200
    description
    The SITRANS TH200 is designed to support all common RTD , thermocouple, resistance and millivolt sensors. With modem and SIPROM Tsoftware, its setup is fast and simple. This configuration tool is available for free download. A unique user-friendly interface for viewing diagnostic information. The output current can be read directly without the need to disconnect the 4-20 mA loop with a multimeter. A red / green LED gives the user a sense of work status.
    Siemens temperature transmitter details
    Input resistance thermometer, thermocouple, resistive sensor, DC source output 4 – 20 mA

    Characteristics
    ■  Measurement temperature is represented by a linear output signal
    ■  Provides high precision over the entire ambient temperature range
    ■  Reduce the impact of factory environmental noise
    ■ Alarm signal for open or short circuit of sensor  according to NAMUR 43
    ■ Electromagnetic compatibility (EMC)  according to DIN EN 61326 and NE21
    ■  Built-in cold junction compensation
    ■  Electrical isolation for accuracy and safety in thermocouple applications
    ■  single or double input
    ■  Custom characteristic curves for non-standard sensor applications
    ■  Temperature difference and average temperature measurement
    ■   US , Canada and Europe for explosion protection implementation standards
    ■  Sturdy design, fully filled electronics
     
    SITRANS TH300 
    Universal HART

     description
    The SITRANS TH300 with HART protocol is designed to support all common thermocouples, resistors and millivolt sensors. With SIMATIC PDM or handheld communicators, its setup is fast and simple. A unique user-friendly interface for viewing diagnostic information.It is not necessary to open the 4-20 mA loop, and the output current can be directly read out by means of a multimeter. A red /green LED gives the user a sense of work status.
     
    Details
    Input resistance thermometer, thermocouple, resistive sensor, DC source output 4 – 20 mA , HART

     
    Characteristics
    ■  Measurement temperature is represented by a linear output signal
    ■  Provides high precision over the entire ambient temperature range
    ■  Reduce the impact of factory environmental noise
    ■ Alarm signal for open or short circuit of sensor  according to NAMUR 43
    ■ Electromagnetic compatibility (EMC)  according to DIN EN 61326 and NE21
    ■  Provide built-in cold junction compensation
    ■  Electrical isolation for accuracy and safety in thermocouple applications
    ■  single or double input
    ■  Custom characteristic curves for non-standard sensor applications
    ■  Extended diagnostics: eg delay indicators and timers
    ■  Set the output current for simulation
    ■   US , Canada and Europe for explosion protection implementation standards
    ■  Sturdy design, fully filled electronics
     
    SITRANS TH400 
    fieldbus

    description
    SITRANS TH400 supports PROFIBUS PA or FF bus communication protocols. It is designed to support all common thermocouples, resistors and millivolt sensors. With SIMATIC PDM or AMS and Handheld Communicator (FF) , its setup is fast and simple. Because of its small dimensions, the device allows a flexible installation options even installed in a DIN standard B -type junction box.
    Details
    Input resistance thermometer, thermocouple, resistance type sensor, DC source output PROFIBUS PA , FF

    Characteristics
    ■  Linearization of sensor values
    ■   Provides high precision over the entire ambient temperature range
    ■  Reduce the impact of factory environmental noise
    ■  Sensor open or short circuit warning signal
    ■ Electromagnetic compatibility (EMC)  according to DIN EN 61326 and NE21
    ■  Provide built-in cold junction compensation
    ■  Electrical isolation for accuracy and safety in thermocouple applications
    ■  single or double input
    ■  Custom characteristic curves for non-standard sensor applications
    ■  Temperature difference or average temperature measurement
    ■  Measured value of the second sensor as redundancy
    ■  Extended diagnosis
    ■  Simulation mode
    ■   US , Canada and Europe for explosion protection implementation standards
    ■  Sturdy design, fully filled electronics
    SITRANS TR200
     
    description
    The SITRANS TR200 is designed to support all common RTD , thermocouple, resistance and millivolt sensors. With modem and SIPROM Tsoftware, its setup is fast and simple. This configuration tool is available for free download. A unique user-friendly interface for viewing diagnostic information. The output current can be read directly without the need to disconnect the 4-20 mA loop with a multimeter. A red / green LED gives the user a sense of work status. 
    Details
    Input resistance thermometer, thermocouple, resistive sensor, DC source output 4 – 20 mA

     
    Characteristics
    ■  Measurement temperature is represented by a linear output signal
    ■  Provides high precision over the entire ambient temperature range
    ■  Reduce the impact of factory environmental noise
    ■ Alarm signal for open or short circuit of sensor  according to NAMUR 43
    ■ Electromagnetic compatibility (EMC)  according to DIN EN 61326 and NE21
    ■  Electrical isolation for accuracy and safety in thermocouple applications
    ■  single or double input
    ■  Custom characteristic curves for non-standard sensor applications
    ■  Temperature difference and average temperature measurement
    ■   US explosion protection implementation standards
    ■  Sturdy design, fully concentrated filling electronics
     
    SITRANS TR300 
    Universal HART

    description
    The SITRANS TR300 with HART protocol is designed to support all common thermocouples, resistors and millivolt sensors. With SIMATIC PDM or handheld communicators, its setup is fast and simple. A unique user-friendly interface for viewing diagnostic information.The output current can be read directly without the need to disconnect the 4-20 mA loop with a multimeter. A red / green LED gives the user a sense of work status.
     
    Details
    Input resistance thermometer, thermocouple, resistive sensor, DC source output 4 – 20 mA , HART

    Characteristics
    ■   Measurement temperature is represented by a linear output signal
    ■   Provides high precision over the entire ambient temperature range
    ■   Reduce the impact of factory environmental noise
    ■ Alarm signal for open or short circuit of sensor   according to NAMUR 43
    ■ Electromagnetic compatibility (EMC)   according to DIN EN 61326 and NE21
    ■   Electrical isolation for accuracy and safety in thermocouple applications
    ■   single or double input
    ■   Custom characteristic curves for non-standard sensor applications
    ■   Temperature difference and average temperature measurement
    ■   Extended diagnostics: eg delay indicators and timers
    ■   Set the output current for simulation
    ■   European explosion protection implementation standards
    ■  Sturdy design, filled electronics
     

    Rich temperature transmitter for SITRANS TW control room
     
    description
    SITRANS TW is a further development of the thousands of proven SITRANS T for four-wire systems in the mounting rail housing Many of its new features set a new standard in the field of temperature transmitters. Its diagnostic and simulation capabilities provide the necessary assistance during commissioning and operation. With SIMATIC PDM , SITRANS TW 's HART interface makes it easy to adapt to any measurement task.
    With the simulation function, the physical values ​​can be reset. This allows the entire signal path without tools to be tested as fast as the control system. The drag delay pointer function adjusts the minimum and maximum process variables of the measurement system.
    All SITRANS TW control room equipment is available in intrinsically safe and intrinsically safe for extreme conditions.
     
    Details
    Resistance Thermometer, Thermocouple, Resistive Sensor, DC Source, Current Source 
    0/4 – 20 mA, HART
    0/2 – 10 V, HART
    Characteristics
    ■  Explosion-proof protection with sensors for hazardous areas [EEx ia] or [EEx ib]
    ■  Temperature linearity of all temperature sensors
    ■  All temperature sensors have linear temperature characteristics
    ■  Diagnostic function
    ■  From the pointer function
    SITRANS TF
    description
    SITRANS TF is used where other transmitters are not competent. The main point is its IP67 protection.
    SITRANS TF is made of sturdy aluminum die-cast or durable stainless steel. It converts the resistance thermometer, thermocouple,Ohm and mV signals into a DC current that is unrelated to the load , or a digital signal that is based on the fieldbus standardPROFIBUS PA or FF . The remotely mounted sensor prevents the transmitter from being heated to high temperatures; there is no shock due to the split installation with the sensor. For locations that are difficult to access, you can remotely install the SITRANS TFin an accessible location and read measurements from a freely programmable digital display. For all 4-20 mA signals, you can even use the transmitterless SITRANS TF as a field display unit. All SITRANS TFs are intrinsically safe or flameproof.
     
    Details
    Input resistance thermometer, thermocouple, resistance type sensor, DC source output model:

     
    4-20mA , with HART 's 4-20mA , PROFIBUS PA or Foundation Fieldbus
     
    Characteristics
    ■  Displaying measured values ​​via a digital display
    ■  Sturdy double chamber housing made of aluminum die-cast or stainless steel
    ■  Test terminal that can directly read out the output signal without interrupting the current cycle
     SITRANS TF280 
    Wireless HART Temperature Transmitter

     
         

     



    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ:
    -------------------------------
    CÔNG TY TNHH THIẾT BỊ CÔNG NGHIỆP TTH
    Trụ sở: số 124 ngõ 79 Yên Hoà-Cầu giấy-HN
    Kinh doanh 1 : 0816.861.515
    Kinh doanh 2 : 0836.861.515
    Kinh doanh 3 : 0926.511.515
    Kinh doanh 4 : 0916.861.515
    Kinh doanh 5 : 0888.868.515
    Kinh doanh 6 : 0917.971.515
    Website: http://tanthanh-automation.com
    Website: http://thietbitudongtanthanh.com
    Website: http://diencongnghieptanthanh.com
    Email: tthkinhdoanh@gmail.com
    Email: tthkinhdoanh01@gmail.com

  • Kết nối với chúng tôi