Product name: LWF series displacement sensor
Pull rod type displacement sensor LWF-A1/V1/V2
Range: 0...50mm...1420mm
Linear accuracy: ±0.2% MB
output: 4...20mA,0. ..10V,0...5V
customized options ( voltage output):
1. LWF-V2 output ( 0-5V DC ) or LWF-V1 ( 0-10V DC )
2. Three-wire system (terminal 1 : Power + , Terminal 2 : Output + , Terminal 3 : Common)
3. Four-wire system (Terminal 1 : Power + , Terminal 2 : Output + , Terminal 3 : Output- , Terminal4 : Power supply- )
Customized option LWF-A1 ( current output 4-20mA ):
1. Two -wire system (Terminal 1 : Output + , Terminal 2 : Input + )
2. Three-wire system (Terminal 1 : Power + , Terminal 2 : Output + , Terminal 3 : Common)
3. Four-wire system (Terminal 1 : Power + , Terminal 2 : Output + , Terminal 3 : Output- , Terminal 4 : Power- ) VOLFA pull rod sensor (electronic ruler), yes Resistance signal output, analog signal output, digital signal output ,
Conductive plastic resistance rail, the measuring rod is self-resetting by spring drive, RS422 , RS485 communication output, directly connected to PC/
PLC, VOLFA sensor is mainly used for automation control, rail transit, etc.
LWF | 0` | 50 | 75 | 100 | 130 | 150 | 175 | 200 | 225 | 250 | 275 | 300 | 350 | 375 | 400 |
Effective electrical travel | mm | 51 | 76 | 102 | 132 | 152 | 177 | 202 | 228 | 254 | 279 | 304 | 355 | 381 | 406 |
Mechanical stroke | mm | 55 | 80 | 106 | 136 | 156 | 181 | 206 | 232 | 258 | 283 | 308 | 359 | 385 | 410 |
Resistance value ±20% | kΩ _ | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 | 5 |
Linearity | % | 0.2 |
Resolution | r | Infinite |
recommended current | mA | <10 |
Operating temperature | °C | -40 to +120 |
Protection class | IP | IP54(Standard),IP65(Optional) |
starting power | N | 1.2N (IP54), 5N (IP65 ) |
power | W | 2W - 10W |
maximum working voltage | V | 30V DC |
life | | 100 million times |
shock | G | IEC 68-2-6 : 1982 10G |
impact | G | IEC 68-2-29 : 1968 40G |
size A | mm | 117 | 142 | 168 | 198 | 218 | 243 | 268 | 294 | 320 | 345 | 370 | 421 | 447 | 472 |