Công ty TNHH công nghệ số Tân Thành

XD-NES-ED left expansion ED module XD-COBOX-ED communication module PLC Wuxi Xinjie Electric Co., Ltd.

  • Đăng ngày 24-10-2022 03:09:49 PM - 734 Lượt xem
  • Mã sản phẩm: S004188

  • Tình trạng sản phẩm:


    XD3 series basic unit
    XD3 series standard PLC, including 16, 24, 32, 48, 60 point specifications. It has complete functions and can meet the needs of most users.

    Product Features
    XD3 series standard PLC, including 16, 24, 32, 48, 60 point specifications.
    It has complete functions and can meet the needs of most users.
    Speed ​​and capacity are greatly improved compared to XC series
    Input type: NPN
    Output type: Transistor (T), Relay (R)
    Power supply specification: AC220V
    Support X-NET fieldbus function
    Support high-speed counting (up to 80KHz), pulse output (up to 100KHz) , frequency measurement and other special functions as
    standard with USB port, used for programming download
    Support 1~10 expansion modules, 1 expansion ED, 1~2 expansion BDs (16 points are not supported)

     

    List of models

    model

    Enter the number of points

    (DC24V)

    output points

    (R, T)

    AC power

    DC power

     

    relay output

    transistor output

    Transistor relay mixed output

    relay output

    transistor output

    Transistor relay mixed output

    N

    P

    N

    type

    XD3-16R-E

    XD3-16T-E

    XD3-16RT-E

    XD3-16R-C

    XD3-16T-C

    XD3-16RT-C

    8 o'clock

    8 o'clock

    XD3-24R-E

    XD3-24T-E

    XD3-24RT-E

    XD3-24R-C

    XD3-24T-C

    XD3-24RT-C

    14:00

    10 O'Clock

    XD3-32R-E

    XD3-32T-E

    XD3-32RT-E

    XD3-32R-C

    XD3-32T-C

    XD3-32RT-C

    18:00

    14:00

    XD3-48R-E

    XD3-48T-E

    XD3-48RT-E

    XD3-48R-C

    XD3-48T-C

    XD3-48RT-C

    28 o'clock

    20 o'clock

    XD3-60R-E

    XD3-60T-E

    XD3-60RT-E

    XD3-60R-C

    XD3-60T-C

    XD3-60RT-C

    36 o'clock

    24 o'clock

    P

    N

    P

    type

    XD3-16PR-E

    XD3-16PT-E

    -

    XD3-16PR-C

    XD3-16PT-C

    XD3-16PRT-C

    8 o'clock

    8 o'clock

    XD3-24PR-E

    XD3-24PT-E

    XD3-24PRT-E

    XD3-24PR-C

    XD3-24PT-C

    XD3-24PRT-C

    14:00

    10 O'Clock

    XD3-32PR-E

    XD3-32PT-E

    XD3-32PRT-E

    XD3-32PR-C

    XD3-32PT-C

    XD3-32PRT-C

    18:00

    14:00

    XD3-48PR-E

    XD3-48PT-E

    XD3-48PRT-E

    XD3-48PR-C

    XD3-48PT-C

    XD3-48PRT-C

    28 o'clock

    20 o'clock

    XD3-60PR-E

    XD3-60PT-E

    XD3-60PRT-E

    XD3-60PR-C

    XD3-60PT-C

    XD3-60PRT-C

    36 o'clock

    24 o'clock

    Note: PNP type PLC is a customized machine.

     

    Basic Specifications

    project

    Specification

    insulation voltage

    DC 500V 2MΩ or more

    Anti-noise

    Noise voltage 1000Vp-p 1us pulse for 1 minute

    Air

    No corrosive, flammable gas

    ambient temperature

    0℃~60℃

    environment humidity

    5%~95% (no condensation)

    USB port

    USB fast download port, connect PC to download/upload/monitor

    PORT1

    RS232, connect to the host computer, man-machine interface programming or debugging

    PORT2

    RS485, connected to smart meters, inverters, etc.

    PORT3

    Extended ED communication port

    Install

    It can be fixed with M3 screws or directly mounted on the guide rail ※2

    Ground (FG)

    The third type of grounding (not to be grounded in common with the strong current system) ※3

     

    Performance Specifications

    project

    Specification

    program execution

    Cyclic scan method

    programmatically

    Combined use of instructions and ladder diagrams

    processing speed

    0.05us

    power outage

    Use FlashROM and lithium battery (3V button battery)

    User program capacity*1

    256KB;

    I/O

    points

    ※2

    total points

    16 o'clock

    24 o'clock

    32 o'clock

    48 o'clock

    60 points

    enter

    points

    8 o'clock

    X0~X7

    14:00

    X0~X15

    18:00

    X0~X21

    28 o'clock X0~X33

    36 points X0~X43

    output

    points

    8 o'clock

    Y0~Y7

    10 O'Clock

    Y0~Y11

    14:00

    Y0~Y15

    20:00 Y0~Y21

    24:00 Y0~Y27

    Internal coil (X) ※3

    1280 points: X0~X77, X10000~X11777, X20000~X20177, X30000~X30077

    Internal coil (Y) *4

    1280 points: Y0~Y77, Y10000~Y11777, Y20000~Y20177, Y30000~Y30077

    inner coil

    (M, HM)

    11008 points

    M0~M7999【HM0~HM959】※5

    Special use ※6 M0~SM2047

    Process(s)

    1152 points

    S0~S1023【HS0~HS127】

    Timer (T)

    points

    672 points

    T0~T575【HT0~HT95】

    Specification

    100ms timer: set time 0.1~3276.7 seconds

    10ms timer: set time 0.01~327.67 seconds

    1ms timer: set time 0.001~32.767 seconds

    Counter (C)

    points

    672 points

    C0~C575【HC0~HC95】

    Specification

    16-bit counter: set value K0~32,767

    32-bit counter: set value -2147483648~+2147483647

    Data Register (D)

    11048 words

    D0~D7999【HD0~HD999】※5

    Special use ※6 SD0~SD2047

    FlashROM register

    (FD)

    8144 words

    FD0~FD6143

    Special use ※6 SFD0~SFD1999

    High-speed processing function

    High-speed counting, pulse output, external interrupt

    password protection

    6-bit length ASCII

    Self-diagnostic function

    Power-on self-test, watchdog timer, syntax check

    Notes:

    ※1: User program capacity, refers to the maximum program capacity when downloading confidentially.

    ※2: The number of I/O points refers to the number of terminals that the user can access and output signals from the outside.

    ※3: X, refers to the internal input relay, the X exceeding the number of I points can be used as an intermediate relay.

    ※4: Y, refers to the internal output relay, the Y exceeding the number of O points can be used as an intermediate relay.

    ※5: The [] mark is the default power-off hold area and cannot be changed.

    ※6: For special use, it refers to the special-purpose registers occupied by the system and cannot be used for other purposes.

    ※7: The numbers of input coils, output relays/transistors are octal numbers, and the numbers of other memories are decimal numbers.

    *8: I/Os that are not actually connected to peripherals can be used as fast internal relays.

     

    Function configuration table

    ×Not supported √Supported

    series and

    points

    USB port

    232 ports

    communication

    expand

    module

    expand

    BD board

    High-speed counting channels

    Number of pulse output channels (T type

    /RT type)

    External Interrupt

    485

    communication

    free

    communication

    increment

    model

    AB phase

    XD3 series

    XD3-16

    1

    1

    10 pieces

    ×

    3

    3

    2

    6

    XD3-24

    1

    1

    10 pieces

    1 block

    3

    3

    2

    10

    XD3-32

    1

    1

    10 pieces

    1 block

    3

    3

    2

    10

    XD3-48

    1

    1

    10 pieces

    2 pieces

    3

    3

    2

    10

    XD3-60

    1

    1

    10 pieces

    2 pieces

    3

    3

    2

    10

    Note: Clock functionality is standard on all models.

     

         

     



    TÂN THÀNH CAM KẾT

    • Sản phẩm, hàng hóa chính hãng.
    • Giá cả cạnh tranh.
    • Dịch vụ chăm sóc khách hàng tận tâm.

    Thông Tin Công Ty

    Đã thông báo

     


    THÔNG TIN LIÊN HỆ:
    -------------------------------
    CÔNG TY TNHH THIẾT BỊ CÔNG NGHIỆP TTH
    Trụ sở: số 124 ngõ 79 Yên Hoà-Cầu giấy-HN
    Kinh doanh 1 : 0816.861.515
    Kinh doanh 2 : 0836.861.515
    Email: tthkinhdoanh@gmail.com
    Email: tthkinhdoanh01@gmail.com

  • Kết nối với chúng tôi